ANALYSIS OF THE VENTILATION AIR FLOW RATE FOR RENEWAL OF WINDOWS
Journal Title: Вісник Національного університету "Львівська політехніка". Серія "Теорія та практика будівництва" - Year 2017, Vol 0, Issue 877
Abstract
Replacement of old wooden windows in a new plastic windows, in the old buildings, we achieve the massive reducing heat loss of the building. New windows are characterized by better tightness. The question is, how much more are reduce the uncontrolled ventilation. In the article is presented the experimental measurement indoor air quality in the room in two phases. In the first phase is in the room installed 55 year old wood window. In the second phase is in the same room installed new plastic window. From the experimental measurement indoor air quality is calculated intensity of ventilation – infiltration. These resultant intensity of ventilation are reciprocally compared. The aim of the article is to find, on the basis of the experimental measurements, the difference in volume flow of air in the room by infiltration, which caused by the replacement of the old wooden window with a new plastic window with insulating double glazing. According to the analysis, it can be stated that by replacing the old wooden window in the room with a new plastic window, the volume of air flow caused by the infiltration decreased by approximately 73 %. The total window heat loss was reduced by approximately 46%.
Authors and Affiliations
P. Kapalo
Energy efficiency of domestic hot water distribution system
The aim of paper is to analyze the thermal losses of domestic hot water (DHW) distribution system. There were used calculation methods by valid EN standard for energy performance of building. The analysis of energy perfo...
Покращення експлуатаційних властивостей керамічної цегли поверхневим модифікуванням поверхні
In the article there are substantiated and determine the optimal composition of protective covering by the mathematical planning method with taking into account the influence of protective covering on water absorption, a...
ОПТИМІЗАЦІЯ СКЛАДУ ЦЕМЕНТОҐРУНТУ З МЕТОЮ ПІДВИЩЕННЯ ЙОГО ФІЗИКО-МЕХАНІЧНИХ ПОКАЗНИКІВ
In order to ensure long-term durability and increase the bearing capacity of clay soils, it is recommended to strengthen them with binder materials. For this purpose, lime and cement are used as binder materials. In orde...
Application of CFD for interior flow analysis influenced by exterior conditions
The aim of the paper is the presentation of application CFD analisys for interior flows in chimneys and flats in a building. It is a summary of a case study of fatal intoxication by carbon monoxide coming from a gas heat...
Аналіз та оцінка ефективності використання теплової ізоляції в опалювальній котельні
The heating supply of residential areas in many cities of Ukraine is central. The heat sources of central heating are heating boiler houses with hot water boilers. Heating boiler houses, usually located far from resident...