Analyzing Subvisible Particles in Protein Drug Products: a Comparison of Dynamic Light Scattering (DLS) and Resonant Mass Measurement (RMM)
Journal Title: The AAPS Journal - Year 2014, Vol 16, Issue 3
Abstract
Aggregation is common in protein drug manufacture, and while the effects of protein particulates are under investigation, many techniques applicable for their characterization have been recently developed. Among the methods available to characterize and quantify protein aggregates, none is applicable over the full size range and different methods often give conflicting results. The studies presented here compare two such methods: dynamic light scattering (DLS) and resonant mass measurement (RMM). The performance of each method was first characterized using polystyrene particle size standards (20, 60, 100, 200, 400, and 1,000 nm) over a range of concentrations. Standard particles were measured both singly and in binary mixtures containing 20 nm particles at a fixed concentration (1014 particles/mL) and various concentrations of one of the other particle sizes (i.e., 60, 100, 200, 400, or 1,000 nm). DLS and RMM were then used to detect unknown aggregate content in stressed samples of IgG. Both instruments were shown to have a working range that depends on particle size and concentration. In binary mixtures and polydisperse solutions, DLS was able to resolve two species in a manner dependent on both concentration and particle size. RMM was able to resolve particles above 200 nm (150 nm for protein) at concentrations below 109 particles/mL. In addition, dilution was evaluated as a technique to confirm and quantify the number of particles in solution.
Authors and Affiliations
Jainik Panchal, Joseph Kotarek, Ewa Marszal, Elizabeth M. Topp
Effect of rise in simulated inspiratory flow rate and carrier particle size on powder emptying from dry powder inhalers
The purpose of this study was to evaluate the effect of carrier particle size and simulated inspiratory flow increase rate on emptying from dry powder inhalers (DPIs). Several flow rate ramps were created using a compute...
A Semi-mechanistic Model for the Effects of a Novel Glucagon Receptor Antagonist on Glucagon and the Interaction Between Glucose, Glucagon, and Insulin Applied to Adaptive Phase II Design
A potent novel compound (MK-3577) was developed for the treatment of type 2 diabetes mellitus (T2DM) through blocking the glucagon receptor. A semi-mechanistic model was developed to describe the drug effect on glucagon...
Monitoring intracellular pH changes in response to osmotic stress and membrane transport activity using 5-chloromethylfluorescein
Intracellular free H+ concentration (pHi) responds to numerous extracellular stimuli. The use of fluorescent indicator dyes to measure pHi is strongly influenced by the ability of target cells to retain activated dye wit...
Early Engineering Approaches to Improve Peptide Developability and Manufacturability
Downstream success in Pharmaceutical Development requires thoughtful molecule design early in the lifetime of any potential therapeutic. Most therapeutic monoclonal antibodies are quite similar with respect to their deve...
Antibody Drug Conjugates: Design and Selection of Linker, Payload and Conjugation Chemistry
Antibody drug conjugates (ADCs) have emerged as an important pharmaceutical class of drugs designed to harness the specificity of antibodies with the potency of small molecule therapeutics. The three main components of A...