APPLICATION OF ION CHROMATOGRAPHY COUPLED WITH PULSE AMPEROMETRIC DETECTION TO DETERMINE MYO–INOSITOL CONTENT IN PLANT COMPONENTS OF FEED

Journal Title: Żywność. Nauka. Technologia. Jakość - Year 2011, Vol 18, Issue 3

Abstract

In the research project, an ion chromatography technique was used as an alternative to microbiological assay to determine the content of myo-inositol in plant components of feeds. The analyzed material consisted of both genetically non-modified and modified varieties of wheat, corn, and soybean, as well as of feed mixtures made on the basis thereof. The contents of total and free inositol were determined as was the content of dialyzable inositol released by in vitro procedure to simulate the intestinal tract of broilers. The myo-inositol was separated on a high-performance, anion-exchange CarboPack PA100 column, and determined using a pulsed amperometric detection procedure (i.e. high performance anion-exchange chromatography with pulse amperometric detection, HPAEC–PAD). The content of total inositol determined by the HPAEC–PAD method ranged between 2572 μg/g (corn-soybean feed) and 3667 μg/g (corn). The data obtained were comparable only with the results of the microbiological assay of both the genetically nonmodified and modified soybean pellets, (2392 and 2636 μg/g, respectively). As regards the other feed components, the results obtained by the HPAEC-PAD method were higher than those obtained using the microbiological method, on average: by 30 to 50 %. In the range of the concentration values from 0.1 to 100 μg/ml, a correlation between the two methods analyzed was the highest in the case of the analysis of myo-inositol released during the in vitro digestion procedure (r = 0.88). In all other cases, the results of the microbiological assay were systematically lower because the liberation of total inositol by the acid hydrolysis was incomplete, and S. cerevisiae ATCC 9080, the micro-organism analyzed, couldn’t utilize the inositol monophosphate to grow. The other possibility was a common presence of hydrophobic aminoacids in soy-containing components of feeds, which could interfere with the system of pulsed amperometric detection.

Authors and Affiliations

Robert Duliński, Anna Starzyńska-Janiszewska

Keywords

Related Articles

FIZYKOCHEMICZNE I SENSORYCZNE CECHY MIĘSA KOGUTÓW I KAPŁONÓW SUSSEX RODU S-66

Celem pracy było porównanie fizykochemicznych i sensorycznych cech jakości mięsa kogutów i kapłonów. Badaniami objęto 80 kogutków Sussex (S-66), które przydzielono losowo do dwóch grup po 40 sztuk w każdej. Grupę I stano...

[i][/i]COMPARISON OF YIELDING AND PROTEIN CONTENT IN COMMON OATS/NARROW-LEAVED LUPINE MIXTURES

The objective of the research (2004 - 2006) was to determine the yield of seeds, straw, crop residues, and total protein in mixtures of oats and narrow-leaved lupine depending on the content proportions of those specie...

 DETERMINING THE CONTENT OF ETHANOL USING ENZYMATIC METHOD IN ALCOHOLIC AND NON-ALCOHOLIC BEVERAGES

 The objective of the study was to assess the usefulness of enzymatic method and analytical „Alkotest” kit applied to perform a quantitative analysis of the ethanol content in wines, fruit drinks and juices, meads,...

Ryby oraz odpady rybne jako źródło składników bioaktywnych oraz surowiec dla przemysłu energetycznego

Celem niniejszej pracy była charakterystyka mięsa ryb oraz odpadów przemysłu rybnego jako źródła cennych składników odżywczych oraz surowca dla przemysłu energetycznego. Mięso ryb i przetwory rybne są ważnym elementem zr...

Download PDF file
  • EP ID EP158010
  • DOI 10.15193/zntj/2011/76/173-185
  • Views 52
  • Downloads 0

How To Cite

Robert Duliński, Anna Starzyńska-Janiszewska (2011). APPLICATION OF ION CHROMATOGRAPHY COUPLED WITH PULSE AMPEROMETRIC DETECTION TO DETERMINE MYO–INOSITOL CONTENT IN PLANT COMPONENTS OF FEED. Żywność. Nauka. Technologia. Jakość, 18(3), 173-185. https://europub.co.uk/articles/-A-158010