Assessment of cleaning efficacy of Mtwo NiTi rotary files and Hand K-files: A comparative in-vitro study

Abstract

Background: Rotary instruments enhance the quality of obturation by providing conical shape to the root canal. Abstract Nickle titanium (NiTi) alloy instruments inherent flexibility that allows the files to preserve the original anatomy of curved canals and reduce the chances of procedural errors. The present study was designed to comparatively evaluate the cleaning efficacy of Mtwo NiTi rotary files and hand K-files. Material and methods: After approval of the study protocol, we selected 30 extracted maxillary incisors. The teeth were randomly grouped into three groups, Group 1, Group 2 and Group 3 with 10 teeth in each group. The instrumentation of specimens of group 1 was done using stainless steel K-files, in group 2 was done using Mtwo NiTi rotary files and in group 3 only irrigation was done without any instrumentation (Control group). After completion of instrumentation, the specimens were decalcified and claed. The cleared specimens were viewed under stereo microscope at 10X for checking the amount of residual india ink at coronal, middle and apical region of the canals and scored from 0 to 3. Results: On comparing the control group with K-files and Mtwo rotary files, we observed that both the techniques were able to remove the ink from the canals. Statistically significant difference was observed in the apical, middle and coronal thirds of root canals on comparing control group with Group1 and 2. On comparison between Group 1 and 2, non-significant difference was observed in the cleaning efficiency of the canals at apical, middle and coronal region. Conclusion: Based on the findings of present study, we conclude that manual K-files were similar in cleaning effectiveness to Mtwo rotary systems in cleaning tooth root canals.

Authors and Affiliations

Ashu Jhamb

Keywords

Related Articles

Evaluation of the Treatment Outcomes in cases with Bile Leakage following Cholecystectomy

Background: The most desirable treatment of choice of treatment of bile leakage following cholecystectomy is Endoscopic retrograde cholangiopancreatography (ERCP) with placement of a biliary stent or drain. Aim of the st...

Efficacy of sodium hypochlorite and sodium perborate in strains removal in acrylic resin

bstract polymethylmethacrylate type of resin. The present study was conducted to compare the efficacy of sodium hypochlorite and sodium perborate in strains removal in acrylic resin. Materials & Methods: The present stud...

Assessment of Vitamin D Status among Children of Known Population: An Observational Study

Background: Hence; we planned the present study to assess the vitamin D status in a known paediatric population. Materials &methods: The present study included assessment of vitamin D status among children of known popul...

Activity Limitation and Participation Restriction in Adults with Auditory Neuropathy Spectrum Disorder

Background: Auditory Neuropathy Spectrum Disorder (ANSD) isa hearing disorder which may be Abstract characterized by normal or near normal hearing, or hearing loss ranging between mild to severe; but always associated wi...

Hemoglobin D Disease: An Atypical Presentation

Haemoglobinopathies are characterised by structurally abnormal haemoglobin variants of the normal adult haemoglobin (HbA) which led to increase hemolysis and dependency on blood transfusion for maintaining normal range h...

Download PDF file
  • EP ID EP519677
  • DOI -
  • Views 117
  • Downloads 0

How To Cite

Ashu Jhamb (2017). Assessment of cleaning efficacy of Mtwo NiTi rotary files and Hand K-files: A comparative in-vitro study. Harsukh Educational Charitable Society International Journal of Community Health and Medical Research, 3(3), 2-6. https://europub.co.uk/articles/-A-519677