A preliminary assessment of the possibilities of utilizing domestic waste water as a low-temperature source for a heat pump is made in the paper. Based on energy balance and heat transfer equations and analysis of thermodynamic cycle of the heat pump it is shown that in case of domestic usage this source can be regarded mostly as an opportunity to improve the efficiency and reliability of the heat pump. In conditions of Ukraine such type of thermal energy source can cover small share of heat demand – 8…15 %. Although it is possible to increase this share to 30…40 % with the help of existing technologies of improving thermal performance in a building. Possible solutions of utilizing domestic used water in home heating equipment are proposed and analyzed

Authors and Affiliations

V. Voloshchuk, O. Hrytsyna

Keywords

Related Articles

Influence of magnetic field characteristics during water treatment on the parameters of capillary-porous and colloidal capillary-porous bodies

Technological systems with water magnetization give unstable results. The reason is a lack of research of the influence of the water magnetization parameters. The hypotheses on expediency of application of high-frequency...

Conceptual Foundations for Creation of Mechatronic Control Systems for the Microclimate of Museum Premises Using Fuzzy Logic Controllers

Abstract. A supervising algorithm based on the maintenance of the desired discomfort index (which is the intersection of two indexes: museum peaces and human body) via a fuzzy-controller dealing with museum premises’ mic...

Development of Methodology of Thermal Energy Distribution on Heating Between Consumers of The Multi-Apartment Building

According to the Law of Ukraine "On Commercial Accounting for Thermal Energy and Water Supply", the accounting of heat energy consumption in buildings should be carried out by building units of commercial accounting of t...

Experimental Studies of Combustion of Biofuel in a Fluidized Bed

Results of experimental studies of heat losses due to mechanical underburning of various types of wood fuel in the furnaces of the fluidized bed are presented. Influence of the bed temperature and the air excess factor o...

Parameters of a Heat Supply System at a Lower Temperature Chart

In the current Ukrainian economic situation, operation of heat supply systems is under low temperature of the heatingsystem water. The higher temperature chart of 95/70°С is inexpedient because of high cost of fuel. The...

Download PDF file
  • EP ID EP556983
  • DOI -
  • Views 82
  • Downloads 0

How To Cite

V. Voloshchuk, O. Hrytsyna (2016). Assessment of Domestic Waste Water Potential for In-House Heat Pump Systems. Вентиляція, освітлення та теплогазопостачання, 20(), 81-89. https://europub.co.uk/articles/-A-556983