Parameters of a Heat Supply System at a Lower Temperature Chart

Abstract

In the current Ukrainian economic situation, operation of heat supply systems is under low temperature of the heatingsystem water. The higher temperature chart of 95/70°С is inexpedient because of high cost of fuel. The experience of such countries as Denmark, Germany, Finland, Sweden, and Holland with developed centralized heat supply proves the necessity of priority equipment of local heat distribution and metering stations (HDMS) of the building with an automatic control system. After that, the technology with a reduced temperature chart should be applied. Therefore, the modernization of heat supply systems in Ukraine aimed to applying the reduced temperature chart will require the transition to closed independent heating systems, to qualitative and quantitative regulation, to automation of HDMS consumers. In the paper, the results of the numerical study of the constructive and operating parameters of influence of a heat supply network on the selection of the optimum temperature and the flow of the heating-system water in a district heating system (DHS) are considered. The significant influence of the heating characteristic k·F [W / K] of a building on the parameters of the DHS has been determined, the actual values of k·F of some residential buildings have been determined according to field studies. The obtained actual data is lower than the calculated values of k·F, which requires increased temperature of the heat carrier in the supply pipeline. Reducing the temperature chart will require a reduction in energy consumption in residential and administrative buildings

Authors and Affiliations

I. O. Redko, A.  Redko Redko, A. Priymak, N. Lantsberg

Keywords

Related Articles

Conceptual Provisions for Long-Term Planning in the Field of District Heating

It is necessary to improve the state policy in the sphere of long-term planning of modernization and development of district heating systems. There are links to Ukrainian and European documents. Features of long-term pla...

Modeling of the Iemperature Mode of the Room with Warm Floor in SolidWorks

This article discusses the mathematical modeling researches in SolidWorks. They are necessary to determine the temperature mode of the room in order to optimize the usage of electrothermal heating systems with constant p...

Optimization of the Parameters of the Heat Network Under a Reduced Temperature Schedule

The economic and environmental problems of Ukraine lead to decrease the water temperature in heat supply systems. Increasing the cost of fuel made it inappropriate to schedule temperature 95/70. To switch to a lower temp...

Types of Exergy in air conditioning systems and their definition

The results of the determination of the basic material and physical flows in air conditioning systems and their expressions in terms of exergy are given. The analytical dependence in a convenient form for engineering ca...

Mechanism оf Protective Action оf Some Surfactants іn the Network Water оf Centralized Heat Supply Systems

Тhe problem of controlling scale formation and corrosion is very acute and relevant for heat power engineering. Particularly acute problem is in centralized heat supply systems in the cities of Eastern Europe and the for...

Download PDF file
  • EP ID EP556273
  • DOI -
  • Views 75
  • Downloads 0

How To Cite

I. O. Redko, A.  Redko Redko, A. Priymak, N. Lantsberg (2018). Parameters of a Heat Supply System at a Lower Temperature Chart. Вентиляція, освітлення та теплогазопостачання, 24(), 42-51. https://europub.co.uk/articles/-A-556273