Assessment of Regulatory Compliances in Diagnostic X-ray Facilities in Tangail District, Bangladesh

Abstract

Due to increasing public demand, diagnostic x-ray facilities are expanding from the city to district even at rural areas faster than ever before in Bangladesh. At the same time radiological safety issues are also becoming the matter of great concern in this area of medical sector. In the present study, a comprehensive investigation is carried out on radiological safety matters in the 34 diagnostic x-ray facilities at Tangail districts in Bangladesh. The main objective of this study is to verify the compliance of regulatory requirements with respect to the radiation safety. The safety parameters are assessed emphasizing particularly on the room size, shielding material at entrance door and control panel and thickness of side walls of x-ray installations. It is very important to investigate the status of regulatory compliance requirements at the stage of designing of an x-ray room. It has been found that 62% facilities maintain the shielding properly and 26% have no shield at all against the radiation. Nearly acceptable room size was found only in the two facilities. Among the facilities few of them use old and non-calibrated x-ray machine. To some extent unexpected dose variation with room size is also observed. The present study on radiological safety status of diagnostic x-ray installations may be a reasonably good presentation of the situation in the country as a whole. The study can contribute significantly to the improvement of radiological safety in near future.

Authors and Affiliations

S Shill

Keywords

Related Articles

A Proposed Probability Model for the Single Male out Migrants from Rural to Urban Areas

The objective of the current work to develop a probability model under the certain assumptions. The model involves several parameters and these are estimated by different method of estimation techniques. Application is m...

Influence of Red Mud Catalyst in the Catalytic Fuel Reformer

The hazardous waste material such as Waste engine oil (WEO) and red mud is recycled in this study. WEO is thermally cracked with red mud catalyst in the catalytic fuel reformer (CFR). The gas obtained from the CFR is con...

A Framework for Medical Assistance using Internet of Things Architecture

Remote monitoring of patient is one of the important areas of research in the medical field. With the advancements in the field of sensors and semiconductors it is possible to monitor a patient and provide him medication...

Epidemiology and Tropical Diseases

Researchers like Dr. Robert Koch, Louis Pasteur, Carlos Chagas, Neisser, Dr. Ronald Ross, David Bruce, Paul Ehrlich, G.H.A Hansen and other different researchers in the science of medicine gave a good contribution in the...

Mitigation of Voltage Complication by A Novel Control Algorithm Based Dynamic Voltage Restorer

This project gives the systematic procedure of the modeling and simulation of a Dynamic Voltage Restorer (DVR) for power quality problem, voltage sag based on Pulse Width Modulation (PWM) technique. This problem is reduc...

Download PDF file
  • EP ID EP221547
  • DOI -
  • Views 107
  • Downloads 0

How To Cite

S Shill (2015). Assessment of Regulatory Compliances in Diagnostic X-ray Facilities in Tangail District, Bangladesh. International journal of Emerging Trends in Science and Technology, 2(2), 1800-1804. https://europub.co.uk/articles/-A-221547