Attenuation of ultrasonic noise in the 10–16 kHz frequency range by earplugs

Journal Title: Medycyna Pracy - Year 2018, Vol 69, Issue 4

Abstract

Background: The aim of the study was to determine attenuation of earplugs for ultrasonic noise in the frequency range of 10–16 kHz. Material and Methods: The attenuation of earplugs in 1/3-octave-bands with the centre frequencies of 10 kHz, 12.5 kHz, and 16 kHz using the REAT (real-ear attenuation at threshold) method based on the measurements of hearing threshold of subjects. The study was carried out for 29 models of earplugs commonly used in the industry designed by various manufacturers, including 13 models of foam earplugs, 10 models of flanged earplugs, 5 models of headband earplugs and one model of no-roll earplugs. Results: The values of the measured attenuation of earplugs are in the range 12.9–33.2 dB for the 10 kHz frequency band, 22.8–35.2 dB for the 12.5 kHz frequency band and 29.5–37.2 dB for the 16 kHz frequency band. The attenuation of earplugs in the frequency range 10–16 kHz has higher values (statistically significant changes) for foam earplugs than flanged earplugs (p = 0.0003 vs. p = 0.0006) or headband earplugs (p = 0.0002 vs. p = 0.04). Conclusions: The tests indicated that there is no uniform relation between the sound attenuation in the frequencies range of 10–16 kH and the catalogue H parameter (high-frequency attenuation value) of earplugs. Therefore, it is not possible to easily predict the attenuation of ultrasonic noise in the frequency range of 10–16 kHz using the sound attenuation data for the normally considered frequency range (up to 8 kHz). Med Pr 2018;69(4):395–402

Authors and Affiliations

Emil Kozłowski, Rafał Młyński

Keywords

Related Articles

CZYNNIKI WPŁYWAJĄCE NA POZIOM BEZPIECZEŃSTWA I INFEKCJE WŚRÓD PRACOWNIKÓW LABORATORIÓW DIAGNOSTYCZNYCH

Wstęp: Celem badania była ocena zagrożenia pracowników laboratoriów diagnostycznych szkodliwymi czynnikami biologicznymi, ze szczególnym uwzględnieniem infekcji (LAI – laboratory acquired infection), czynności o najwi...

Judgment of the morality of an individual responsible for a fatal workplace accident involving subordinates

Background: The aim of the study was to verify the hypothesis that additional information about the perpetrator responsible for the death of subordinates at the workplace may influence the assessment of morality. The art...

Reliability of the Epworth Sleepiness Scale and the Berlin Questionnaire for screening obstructive sleep apnea syndrome in the context of the examination of candidates for drivers

Background: The aim of the study has been to assess the usefulness of the Epworth Sleepiness Scale (ESS) and the Berlin Questionnaire (BQ) for obstructive sleep apnea syndrome (OSAS) screening. The capacity of both tests...

Health state assessment in people sentenced to the penalty of restriction of liberty

Background: Assessment of the health state of people sentenced to the penalty of restriction of liberty makes up a significant percentage of cases annually elaborated in the Department of Forensic Medicine, Poznan Univer...

THE DOSE RECEIVED BY PATIENTS DURING DENTAL X-RAY EXAMINATION AND THE TECHNICAL CONDITION OF RADIOLOGICAL EQUIPMENT

Background: Implementation of X-ray dental examination is associated with the patient's exposure to ionizing radiation. The size of the exposure depends on the type of medical procedure, the technical condition of the X-...

Download PDF file
  • EP ID EP395290
  • DOI 10.13075/mp.5893.00721
  • Views 137
  • Downloads 0

How To Cite

Emil Kozłowski, Rafał Młyński (2018). Attenuation of ultrasonic noise in the 10–16 kHz frequency range by earplugs. Medycyna Pracy, 69(4), 395-402. https://europub.co.uk/articles/-A-395290