Automatic Voltage Regulator and Automatic Load Frequency Control of Electrical Power Plant with Optimal Tuning Controller PID
Journal Title: International Journal for Research in Applied Science and Engineering Technology (IJRASET) - Year 2015, Vol 3, Issue 10
Abstract
this paper deals with an optimal tuned of without controller, Proportional Integral Derivative (PID) controller and Ziegler-Nichols tuned controller for both Automatic Voltage Regulation (AVR) and Load Frequency Control (LFC). As voltage constancy and frequency are important factors in determining the quality of power supply, the control of active power and reactive power is vital to the satisfactory performance of power system. The real power and frequency is controlled by LFC and the reactive power and voltage is controlled by AVR. Various measuring indices settling time, peak amplitude is considered as the performance measures for analyzing the transient response of AVR and LFC.The simulation results of the proposed Ziegler-Nichols tuned with compared PID tuned and without tuned controller. The comparative analysis clearly reveals that the transient response and the robustness are much improved with the proposed Ziegler-Nichols tuned approach over others.
Authors and Affiliations
Ashok Singh, Rameshwar Singh, Rekha Kushwah
Design and Parametric Analysis of Multiband Directional Antenna for Wireless Applications
This paper presents an aperture coupled multiband microstrip antenna for various wireless applications. The antenna consists of microstrip fed slot with a complimentary stub on a single dielectric medium. A reflecting g...
Performance Comparison of Cryptanalysis Techniques over DES
The primary requirement of a good encryption technique is that it is either impossible or difficult to deduce the plaintext out of a ciphertext without the knowledge of key. Cryptanalysis is the technique that violates...
A Research Paper on Heat Transfer in Notch Fin and UN Notch Fin
We studied the experimental observation and simulation for rectangular unnotched fin validated for different thermal load (i.e., 20W, 30W, 40W, 50W) .After that we also simulated different cases (i.e., 20W, 30W, 40W, 50...
Spatial assessment of Heavy Metal Contamination in the Sediments of Kodaikanal Lake, Tamil Nadu, India
Lake sediments, as basic components of our environment; provide food stuff for living organisms. They also serve as a sink and reservoir for a variety of environmental contaminants. Namely when released into aquatic env...
Survey Based on Hadoop
This document gives the information about the HADOOP- big data. Hadoop is the popular open source for storing the big data at a time. It is a powerful tool designed for deep analysis and transformation of very large dat...