Behaviour of Flush End-Plate Connection for Perforated Section

Journal Title: Engineering Heritage Journal (GWK) - Year 2017, Vol 1, Issue 1

Abstract

This paper presents the study on the behaviour of the beam to column connection by using flush endplate connection for I-beam steel section with perforation. Moment rotation and failure pattern of flush end plate connection for perforated section were studied. The model was modelled by using LUSAS software and then analysed with nonlinear finite element analysis. Nineteen models were generated for flush end plate connection with perforated beam section consisting of variable parameters such as opening size, distance between the first opening and column face, and spacing between the openings. The moment resistance and rotational stiffness of the connection are found to be reduced by the presence of the openings. The geometric parameter of the openings affected the behaviour of the connections. It is found that the larger the opening size, the lower the strength and rigidity of the connection. Furthermore, it is found that the presence of openings causes increment in the deflection of the beam. However, some perforated sections with optimum geometric parameters for openings have higher strength to weight and rigidity to weight ratio than normal section without perforation. In this study, the most effective geometric parameter for openings are found to be size of 0.65h, distance between the first opening and column face of 800mm and spacing between openings of 1.3h (h is the depth of the beam web).

Authors and Affiliations

Fatimah De'nan, Nurfarhah Naaim, Lai Chun Leong

Keywords

Related Articles

Phytoremediation of suspended solids and turbidity of palm oil mill effluent (POME) by Ipomea aquatica

Malaysia produces 60 million tons palm oil mill effluent per year. Treatment methods are unable to pass discharge standards. Phytoremediation as a co-treatment could be used for anaerobically treated POME. Direct applica...

CAVITY DETECTION UNDER RE-ENFORCED CONCRETE FLOOR USING GROUND PENETRATION RADAR

Voids underlying engineering re-enforced ground floor could be hazardous and may hinder proposed project objectives, if not adequately detected. Ground penetration radar is non-penetrative and non-destructive technique t...

Behaviour of the Beam to Column Connection for Tapered Steel Section with Perforation

Connections are joints or nodes which are used to joint elements of a structure at a point such that forces can be transferred between them safely. Tapered steel section with perforation is normally used in construction...

FINITE ELEMENT ANALYSIS ON LATERAL TORSIONAL BUCKLING BEHAVIOUR OF I-BEAM WITH WEB OPENING

Lateral torsional buckling may occur in an unrestrained beam. A beam is considered to be unrestrained when its compression flange is free to laterally rotate and laterally displace. In this paper, the finite element anal...

ANALYSIS OF PASSENGERS’ ACCESS AND EGRESS CHARACTERISTICS TO THE TRAIN STATION

Nowadays, the expansions of train networks in Malaysia are dynamically developed. In the future, the railway networks are predicted to give the important role in the development of a sustainable transportation system in...

Download PDF file
  • EP ID EP257028
  • DOI 10.26480/gwk.01.2017.11.20
  • Views 60
  • Downloads 0

How To Cite

Fatimah De'nan, Nurfarhah Naaim, Lai Chun Leong (2017). Behaviour of Flush End-Plate Connection for Perforated Section. Engineering Heritage Journal (GWK), 1(1), 11-20. https://europub.co.uk/articles/-A-257028