Behaviour of Flush End-Plate Connection for Perforated Section

Journal Title: Engineering Heritage Journal (GWK) - Year 2017, Vol 1, Issue 1

Abstract

This paper presents the study on the behaviour of the beam to column connection by using flush endplate connection for I-beam steel section with perforation. Moment rotation and failure pattern of flush end plate connection for perforated section were studied. The model was modelled by using LUSAS software and then analysed with nonlinear finite element analysis. Nineteen models were generated for flush end plate connection with perforated beam section consisting of variable parameters such as opening size, distance between the first opening and column face, and spacing between the openings. The moment resistance and rotational stiffness of the connection are found to be reduced by the presence of the openings. The geometric parameter of the openings affected the behaviour of the connections. It is found that the larger the opening size, the lower the strength and rigidity of the connection. Furthermore, it is found that the presence of openings causes increment in the deflection of the beam. However, some perforated sections with optimum geometric parameters for openings have higher strength to weight and rigidity to weight ratio than normal section without perforation. In this study, the most effective geometric parameter for openings are found to be size of 0.65h, distance between the first opening and column face of 800mm and spacing between openings of 1.3h (h is the depth of the beam web).

Authors and Affiliations

Fatimah De'nan, Nurfarhah Naaim, Lai Chun Leong

Keywords

Related Articles

Behaviour of the Beam to Column Connection for Tapered Steel Section with Perforation

Connections are joints or nodes which are used to joint elements of a structure at a point such that forces can be transferred between them safely. Tapered steel section with perforation is normally used in construction...

RE-ENGINEERING IN CONFINEMENT METHOD

Food delivery system is very popular nowadays. This system is very useful specifically for women that go through their confinement alone. Food for women in confinement is very important to their health. Not only for the...

A Study on the Selection of Suitable Sites for Integrated Smart Trapper System Installation (InSmarts)

Rapid expansion in major towns in Malaysia results in the construction of new drainage system mainly open monsoon or storm drains to cater the increase in surface runoff. This research are to study the suitability of sel...

The Efficiency of Structural Steel Section with Perforated-Corrugated Web Profile Subjected to Shear Loading Condition

Triangular web profile (TriWP) steel section with various combinations of perforation shapes, sizes and layouts of perforation are investigated under shear loading condition. The aim of this study is to determine the str...

RE-CYCLE OF E-WASTE IN CONCRETE BY PARTIAL REPLACEMENT OF COARSE AGGREGATE

A solution for reducing the amount of generated electronic waste in India has become one of a major issue. Globally this problem has taken major part of total solid waste amount. Rectifying this waste is still questionab...

Download PDF file
  • EP ID EP257028
  • DOI 10.26480/gwk.01.2017.11.20
  • Views 70
  • Downloads 0

How To Cite

Fatimah De'nan, Nurfarhah Naaim, Lai Chun Leong (2017). Behaviour of Flush End-Plate Connection for Perforated Section. Engineering Heritage Journal (GWK), 1(1), 11-20. https://europub.co.uk/articles/-A-257028