Abstract

Connections are joints or nodes which are used to joint elements of a structure at a point such that forces can be transferred between them safely. Tapered steel section with perforation is normally used in construction industry due to light weight. The connection modelled in this research is extended end plate welded with tapered beam steel section with perforation and then bolted to UKC front flange of column. This connection was modelled by using Finite Element software, LUSAS to determine the moment rotation curve, deformed shape and maximum displacement of the connection. The results were compared between perforated and non-perforated sections. The dimension of the model sizes are 460 x 200 x 10 mm thickness of endplate, 457 x 191 x82 UKB provided with 0.4h opening size and tapered ratio of 0.3 and 254 x 254 x 73 UKC. The Finite Element models were varied in terms of the distance from first opening to column’s face and spacing between openings. The parameters of the openings affect the connection behaviour in a number of ways. It was found that when the distance between first opening and column face become longer, the effect of openings is eliminated. Moreover, tapered steel beam section with perforation has less moment resistance value than tapered steel beam section without perforation as much as 4.34% to 9.70%

Authors and Affiliations

Fatimah De’nan, Hazwani Hasan, Mohamad Mahzuz

Keywords

Related Articles

NONLINEAR CONTROL STRATEGIES AND PLANNING FOR UNDERACTUATED OVERHEAD CRANES

Underactuated overhead cranes play an important role in engineering and construction, which also make nonlinear control strategies and planning on this basis become the current focus of academic research. Based on schola...

Significant Factors of Key Parameters for Low Medium Cost Housing Demand in Malaysia

Housing is one of the basic needs for human being. In Malaysia, there are most low cost and low medium cost houses being constructed due to high demand which in line with the fourth strategic objective outlined in the 10...

CAVITY DETECTION UNDER RE-ENFORCED CONCRETE FLOOR USING GROUND PENETRATION RADAR

Voids underlying engineering re-enforced ground floor could be hazardous and may hinder proposed project objectives, if not adequately detected. Ground penetration radar is non-penetrative and non-destructive technique t...

RESEARCH ON THE CULTURAL CONSTRUCTION OF HOMELINK REAL ESTATE

Due to many factors, most of HomeLink Real Estate service enterprise culture construction becomes a mere fo rmality, the lack of personality, limit the development of enterprises vitality. Chinese real estate service ent...

ANALYSIS OF THE FUNCTION RELATIONS BETWEEN THE DEPTH OF GAP OR SLOT AND THE SPEED OF VIBRATION IN MILLISECOND MULTIPLE-ROW HOLES BLASTING

In order to analyze the attenuation law of blasting vibration wave through the damping groove, and to explore the function relations between the damping groove depth and damping effect of affiliation; the discussion abou...

Download PDF file
  • EP ID EP259794
  • DOI 10.26480/gwk.01.2017.41.44
  • Views 66
  • Downloads 0

How To Cite

Fatimah De’nan, Hazwani Hasan, Mohamad Mahzuz (2017). Behaviour of the Beam to Column Connection for Tapered Steel Section with Perforation. Engineering Heritage Journal (GWK), 1(1), 41-44. https://europub.co.uk/articles/-A-259794