Bilateral Asymmetrical Fracture Dislocation of Shoulder with Rare Combination of Injuries after Epileptic Seizure: A Case Report

Journal Title: Malaysian Orthopaedic Journal - Year 2017, Vol 11, Issue 1

Abstract

The incidence of bilateral gleno-humeral joint dislocation is rare, is almost always posterior and is usually caused by sports injuries, epi lep tic seizures , electrical shock, or electroconvulsive therapy. Bilateral fracture-dislocation is even rarer, with a few cases reported in the literature. We report an unusual case with dislocation of the both gleno-humeral joints in opposite direction after a seizure episode, with fracture of greater tuberosity on one side and of the lesser tuberosity on the contralateral side. Although there have been a few reports of bilateral asymmetric fracture dislocations of the shoulder in the past, an injury pattern resembling our case has, to the best of our knowledge, not been described in the literature so far. This report includes a detailed discussion regarding the mechanism of injury in a case of asymmetrical dislocation following a seizure episode. At final follow-up, the patient had healed fractures, pain less near normal range of motion with no redislocations.

Authors and Affiliations

Sharma A, Jindal S, Narula MS, Garg S, Sethi A

Keywords

Related Articles

Tincture of Benzoin to Prevent Cast Slippage in Clubfoot

Using tincture of benzoin for clubfoot has been well documented in the literature(4,5). The aim of this letter is to recommend and highlight the use of tincture benzoin to prevent clubfoot cast slippage as its use may no...

Unlocked Nailing vs. Interlocking Nailing for Winquist Type I and II Femoral Isthmus Fractures. Is there a Difference?

Interlocking intramedullary nailing is suitable for comminuted femoral isthmus fractures, but for noncomminuted fractures its benefit over unlocked nailing is debatable. This study was undertaken to compare outcomes of i...

The Digital Doctor: Hope, Hype and Harm at the Dawn of Medicine’s Computer Age

Radiology was the earliest specialty to adopt digital technology. The Picture Archiving and Communication System (PACS) enabled radiology departments to digitise images. In 2000, only 8 percent of U.S. hospitals were usi...

The Outcomes of Selective Nerve Root Block for Disc Induced Lumbar Radiculopathy

Introduction : Use of Selective Nerve Root Block (SNRB) in lumbar region to relieve radicular pain along the course of a particular nerve is being practiced in the recent past. We observed and tabulated therapeutic outco...

The Efficacy of Flavonoid Antioxidant from Chocolate Bean Extract: Prevention of Myocyte Damage Caused by Reperfusion Injury in Predominantly Anaerobic Sports

Background: Use of predominantly anaerobic energy systems such as that seen in 800-meter athlete runners disrupts mitochondrial function as an energy source. Furthermore, it produces free radical substances and causes my...

Download PDF file
  • EP ID EP310502
  • DOI 10.5704/MOJ.1703.011
  • Views 88
  • Downloads 0

How To Cite

Sharma A, Jindal S, Narula MS, Garg S, Sethi A (2017). Bilateral Asymmetrical Fracture Dislocation of Shoulder with Rare Combination of Injuries after Epileptic Seizure: A Case Report. Malaysian Orthopaedic Journal, 11(1), 74-76. https://europub.co.uk/articles/-A-310502