Calculation for Design Peak Time of Commercial Building using Theoretical Analysis in Tropical Climate Country

Abstract

This paper provides the calculating of peak time on various possible hours during operating time. According to the surveys and measurement, the peak time will occur at March due to the facing of glass and April due to the wall and roof . In addition, the value of solar heat gain factor SHGF in March for this building is greater than the April on the direction of East, South and West and the SHGF for April is greater than the March on North based on the latitude of Yangon 16.7875N . According to the theoretical analysis, the peak load occurs at 16hour 4PM in March with the amount of 40.459 KW for 4th floor of building envelope. Aung Ko Ko Lwin | Dr. Soe Soe Nu "Calculation for Design Peak Time of Commercial Building using Theoretical Analysis in Tropical Climate Country" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-5 | Issue-1 , December 2020, URL: https://www.ijtsrd.com/papers/ijtsrd35826.pdf Paper URL : https://www.ijtsrd.com/engineering/mechanical-engineering/35826/calculation-for-design-peak-time-of-commercial-building-using-theoretical-analysis-in-tropical-climate-country/aung-ko-ko-lwin

Authors and Affiliations

Aung Ko Ko Lwin | Dr. Soe Soe Nu

Keywords

Related Articles

Steering Control Adaptive Headlight using Sensor

Nowadays, road safety is one of the priority of the government to avoid accidents. Road safety adopts those methods that can prevent road users from being seriously injured or killed. Most of the accidents happened durin...

Matlab Implementation of Power Quality Improvement Based on Fast Dynamic Control

The paper is based on power quality with fast dynamic control having no isolation transformer. The concept is simulated using famous MATLAB tool and the proposed architecture is based on four switching devices only, form...

Modeling and Simulation of Unified Series Shunt Compensator for Power Quality Improvement

Power Quality in the distribution system is the important issue for industrial, commercial and residential applications. An increasing demond for high quality, reliable electrical power and an increasing number of distor...

Area Efficient Full Subtractor Based on Static 125nm CMOS Technology

A combinational logic circuit is said to be independent of time since it gives the results based on present input not past input. This research is concerned about the comparison between currently existing full subtractor...

Stars of Scientific Thoughts in the Sky of Sanskrit Literatures

Sanskrit is the refined language and its literatures are also refined. So, not only from India, but also from all over the world, the rivers of various types of knowledge has gathered and assembles in that ocean of liter...

Download PDF file
  • EP ID EP692160
  • DOI -
  • Views 112
  • Downloads 0

How To Cite

Aung Ko Ko Lwin (2020). Calculation for Design Peak Time of Commercial Building using Theoretical Analysis in Tropical Climate Country. International Journal of Trend in Scientific Research and Development, 5(1), -. https://europub.co.uk/articles/-A-692160