Abstract

This paper describes the VFTO are usually Transient vervoltages in a gas insulated substation. A few Gas Insulated Substation (GIS) units have been in operation and large number of units are under various stages of installation. These problems include, generation of the overvoltage during Dis-connector operations, line to enclosure faults. The fast transient overvoltages obtained are due to switching operations and with fixed arc resistance and variable arc resistance for different lengths of GIS. The Transients are calculated along with load and it was observed that the transients obtained in 5mts length GIS will affect the system more than that obtained in 10mts length GIS and control of secondary equipment in a Single-phase 220kv GIS. The variable arc resistance is calculated by Toepler’s formulae. The equivalent circuits are developed for the components of GIS and voltages are calculated by using the Matlab 7.8 software 

Authors and Affiliations

M. Kondalu , Dr. P. S. Subramanyam

Keywords

Related Articles

Reliability Analysis of Nanoscale CMOS Device with HCI Effect

The paper focuses on the reliability due to hot carrier effects of CMOS and the HC effect under high gate voltage stress. How these stress factors vary with operating conditions, the required foundry qualification test d...

Blind Image De-convolution In Surveillance Systems By Genetic Programming 

surveillance systems has an important part as a Image acquisition and filtering, segmentation, object detection and tracking the object in that image. In blind image de-convolution .most of the methods requires tha...

Rule Based Technique detecting Security attack for Wireless Sensor network using fuzzy logic  

This paper represents the rule based technique which helps to detect the security attack in the Wireless Sensor network .There are many type of security attack which effects on the wireless sensor network. To demonst...

Calculation of Transients at Different Distances in a Single Phase 220KV Gas insulated Substation  

This paper describes the VFTO are usually Transient vervoltages in a gas insulated substation. A few Gas Insulated Substation (GIS) units have been in operation and large number of units are under various stages of...

Mobile Cloud Computing

Despite increasing usage of mobile computing, using its full potential is difficult due to its problems such as resource scarcity, frequent disconnections, and mobility. Mobile cloud computing can address these problems...

Download PDF file
  • EP ID EP151767
  • DOI -
  • Views 94
  • Downloads 0

How To Cite

M. Kondalu, Dr. P. S. Subramanyam (2012). Calculation of Transients at Different Distances in a Single Phase 220KV Gas insulated Substation  . International Journal of Advanced Research in Computer Engineering & Technology(IJARCET), 1(4), 28-33. https://europub.co.uk/articles/-A-151767