Calibration of Soil Moisture Measurement Using Pr2 Moisture Meter and Gravimetric-Based Approaches

Abstract

The research study strongly focused on creating strong mechanism for measuring and evaluating soil moisture content comparing PR2 capacitance moisture meter and gravimetric approach. PR2 moisture meter shows a better performance accuracy of ± 6%; 0.06 m3/m3 and intercept a0 =1.8; indicating the field is heavy clay. It measures to 1000 mm depth with high precision; while realistic result could not be obtained from gravimetric method at this measuring depth. Therefore, effective soil moisture measuring, monitoring and evaluation can be achieved with PR2 moisture meter.

Authors and Affiliations

Olotu Yahaya, Omoregie Alexander, H. O. Dirisu, A. I. Alhassan

Keywords

Related Articles

Model Equations of Shape Memory Effect - Nitinol

Even it has been already confirmed that SMA’s have high potential for robotic actuators, actuators included in space robotics, underwater robotics, robotics for logistics, safety, as well as “green robotics” (robotics fo...

Overview of the Orientation of Solar Generator Surfaces for Photovoltaic (PV) Systems

One of the most readily, espacialy for households as well as for higher installed power, renewable energy techniques to generate electrical power, are the solar photovoltaic (PV) systems. In the designing process of sola...

The Transport Problem utilized for Machines Optimal Allocation

The present paper presents an optimal allocation mode of the ma-chines in a manner to maximize the profit. Starting from provided data – time standard, technical itineraries, production volume, working regime and continu...

A New Method for Modeling and Control of Hybrid Stepper Motors

Over time the mathematical models of the hybrid stepper motors (HSM) have been developed in various forms. In this paper we propose to use for HSM a model of a two-phase synchronous machine with permanent magnet in which...

Evaluation of Irrigation Technology Adoption in Edo State Nigeria

The acceptance and continuous use of any innovation is the ultimate objective of extension programm. However, extension efforts have failed to avail farmers with some beneficial research-based agricultural technology. Th...

Download PDF file
  • EP ID EP447102
  • DOI -
  • Views 75
  • Downloads 0

How To Cite

Olotu Yahaya, Omoregie Alexander, H. O. Dirisu, A. I. Alhassan (2016). Calibration of Soil Moisture Measurement Using Pr2 Moisture Meter and Gravimetric-Based Approaches. Analele Universitatii "Eftimie Murgu" Resita. Fascicula de Inginerie, 23(1), 369-377. https://europub.co.uk/articles/-A-447102