Calibrator: How Long is it Stable?

Journal Title: International Journal of Clinical Biochemistry and Research - Year 2017, Vol 4, Issue 4

Abstract

Calibration is a process of verifying, by comparison with a calibrator of known quantity for its accuracy and imprecision within its assay range. The calibration so performed will have validity and has to be repeated at the end of the validity. The stated stability of the calibrator material after reconstitution is 24hrs. Due to this limited stability, calibration per se, becomes a costly process since few parameters might require frequent calibration. With every calibration, new set of calibrators have to be used that would add to the cost of calibration and cost per reportable test. There are no literatures available which have studied calibrator stability beyond the manufacture’s stated stability. Since the stability of the analytes are much longer than 24 hours in serum, we wanted to see if the same is applicable in calibrators as the matrix of calibrators is comparable to serum. Calibration data from January 2015 to December 2016 was collected. All calibrators reconstituted for the analytes to be studied were included. We assayed calibrator at day 0 after reconstitution for Glucose, Total cholesterol, Total protein, Iron and Lactate dehydrogenase. The mean at 0 days was compared with the mean for 3 different time intervals beyond 24 hours after storing aliquots at -200C. The calibrator for glucose was stable for up to 8 weeks, total cholesterol for 7 weeks, total protein for 10 weeks, iron for 28 weeks and LDH for 17 weeks.

Authors and Affiliations

Shubha N. Prakash, Anitha Devanath, Ahlad .

Keywords

Related Articles

Current Understanding in the Measurement of Low Density Lipoprotein Cholesterol: A Comparison of Direct Measurement by Homogenous Assays versus Calculations

Background: To compare the results obtained by direct homogenous assay for LDL-C to those obtained by Friedwalds and Anandrajas formulas with the assumption that the results obtained by direct assay are most accurate. Th...

MDM2 promoter polymorphism (rs2279744) and serum estrogen level are associated with increased risk of epithelial ovarian cancer: A case-control study

Introduction Epithelial ovarian cancer EOC is most common malignancy affecting Indian women One of the transcriptional targets of p53 is human homolog of Murine Double Minute 2 Oncogene MDM2 which is a crucial negative r...

Prognostic significance of Ischemia Modified Albumin and role of high sensitive Creactive protein levels in acute ischemic stroke patients

Introduction: Acute ischemic stroke (AIS) is one of the leading cause of death worldwide and the main causes of long-term disability. Brain CT shows no abnormality in the early event of AIS and the infarct may not be see...

A comparative study of serum estrogen and lipid profile in pre-menopausal and post-menopausal women as atherosclerotic risk factors

Objectives: Menopause is the permanent cessation of menstruation; since cardiovascular disease is the leading cause of death among post-menopausal women, which may be due to lower level of estrogen. The present study was...

To study an alteration in biochemical parameters in acute and chronic phase of respiratory acidosis and alkalosis

Introduction: The primary abnormality in respiratory acidosis is retention of CO2 (increased H2CO3) due to impaired alveolar ventilation resulting in a rise in pCO2 causing acidemia. However, respiratory alkalosis occurs...

Download PDF file
  • EP ID EP297455
  • DOI 10.18231/2394-6377.2017.0080
  • Views 66
  • Downloads 0

How To Cite

Shubha N. Prakash, Anitha Devanath, Ahlad . (2017). Calibrator: How Long is it Stable?. International Journal of Clinical Biochemistry and Research, 4(4), 348-353. https://europub.co.uk/articles/-A-297455