Calibrator: How Long is it Stable?

Journal Title: International Journal of Clinical Biochemistry and Research - Year 2017, Vol 4, Issue 4

Abstract

Calibration is a process of verifying, by comparison with a calibrator of known quantity for its accuracy and imprecision within its assay range. The calibration so performed will have validity and has to be repeated at the end of the validity. The stated stability of the calibrator material after reconstitution is 24hrs. Due to this limited stability, calibration per se, becomes a costly process since few parameters might require frequent calibration. With every calibration, new set of calibrators have to be used that would add to the cost of calibration and cost per reportable test. There are no literatures available which have studied calibrator stability beyond the manufacture’s stated stability. Since the stability of the analytes are much longer than 24 hours in serum, we wanted to see if the same is applicable in calibrators as the matrix of calibrators is comparable to serum. Calibration data from January 2015 to December 2016 was collected. All calibrators reconstituted for the analytes to be studied were included. We assayed calibrator at day 0 after reconstitution for Glucose, Total cholesterol, Total protein, Iron and Lactate dehydrogenase. The mean at 0 days was compared with the mean for 3 different time intervals beyond 24 hours after storing aliquots at -200C. The calibrator for glucose was stable for up to 8 weeks, total cholesterol for 7 weeks, total protein for 10 weeks, iron for 28 weeks and LDH for 17 weeks.

Authors and Affiliations

Shubha N. Prakash, Anitha Devanath, Ahlad .

Keywords

Related Articles

Evaluation of Adenosine deaminase, Serum C-reactive protein and alkaline phosphatase activity in Rheumatoid Arthritis patients in Shivamogga district, South India

Introduction & Objectives: Rheumatoid arthritis (RA) is a prototypical inflammatory joint disease. The degree of inflammation is reflected in the extent of joint damage, which further has influence on the quality of life...

The synergistic role of CKMB mass and high sensitivity Troponin T in the diagnosis of Acute Coronary Syndrome

Aim: To determine the synergistic role of CKMB mass (CKMBM) and high sensitivity Troponin T (hs-cTnT) in the diagnosis of Acute Coronary Syndrome (ACS). Study Design: This was a cross-sectional study comprising of 140 in...

Association of 25 OH-Vitamin D and hs-CRPin adults with Essential Hypertension

Essential hypertensionis a typical example of complex, multifactorial trait and a well studied risk factor for cardiovascular disease. hs-CRP is well known marker of inflammation resulting in atherosclerosis and cardiova...

High sensitivity–c reactive protein as an additional marker for increased risk of cardiovascular disease in patients of polycystic ovary syndrome

Background: Polycystic ovary syndrome (PCOS) is the most common endocrine disorder affecting women of reproductive age group with a worldwide prevalence of about 4 to12%1,2 . PCOS is seen in up to 25% of the Caucasians a...

Correlation of lipid profile with tobacco use in cataract patients

Introduction: Human beings are blessed with five special senses and vision is the most precious. Cataract is the major cause of a visual impairment. Tobacco use is a modifiable risk factor for cataract. Dyslipidemia is a...

Download PDF file
  • EP ID EP297455
  • DOI 10.18231/2394-6377.2017.0080
  • Views 54
  • Downloads 0

How To Cite

Shubha N. Prakash, Anitha Devanath, Ahlad . (2017). Calibrator: How Long is it Stable?. International Journal of Clinical Biochemistry and Research, 4(4), 348-353. https://europub.co.uk/articles/-A-297455