Characterization of Particles in Protein Solutions: Reaching the Limits of Current Technologies
Journal Title: The AAPS Journal - Year 2010, Vol 12, Issue 4
Abstract
Recent publications have emphasized the lack of characterization methods available for protein particles in a size range comprised between 0.1 and 10 μm and the potential risk of immunogenicity associated with such particles. In the present paper, we have investigated the performance of light obscuration, flow microscopy, and Coulter counter instruments for particle counting and sizing in protein formulations. We focused on particles 2–10 μm in diameter and studied the effect of silicon oil droplets originating from the barrel of pre-filled syringes, as well as the effect of high protein concentrations (up to 150 mg/ml) on the accuracy of particle characterization. Silicon oil was demonstrated to contribute significantly to the particle counts observed in pre-filled syringes. Inconsistent results were observed between different protein concentrations in the range 7.5–150 mg/ml for particles <10 μm studied by optical techniques (light obscuration and flow microscopy). However, the Coulter counter measurements were consistent across the same studied concentration range but required sufficient solution conductivity from the formulation buffer or excipients. Our results show that currently available technologies, while allowing comparisons between samples of a given protein at a fixed concentration, may be unable to measure particle numbers accurately in a variety of protein formulations, e.g., at high concentration in sugar-based formulations.
Authors and Affiliations
Barthélemy Demeule, Steven Messick, Steven J. Shire, Jun Liu
Biomarkers for Drug-Induced Renal Damage and Nephrotoxicity—An Overview for Applied Toxicology
The online version of this article (doi:10.1208/s12248-011-9301-x) contains supplementary material, which is available to authorized users.
Stable Isotope Dilution Mass Spectrometry for Membrane Transporter Quantitation
This review provides an introduction to stable isotope dilution mass spectrometry (MS) and its emerging applications in the analysis of membrane transporter proteins. Various approaches and application examples, for the...
Erratum to: Dissolution Similarity Requirements: How Similar or Dissimilar Are the Global Regulatory Expectations?
Physiologically Based Pharmacokinetic Models in the Prediction of Oral Drug Exposure Over the Entire Pediatric Age Range—Sotalol as a Model Drug
In recent years, the increased interest in pediatric research has enforced the role of physiologically based pharmacokinetic (PBPK) models in pediatric drug development. However, an existing lack of published examples co...
Pediatric Biopharmaceutical Classification System: Using Age-Appropriate Initial Gastric Volume
The online version of this article (doi:10.1208/s12248-016-9885-2) contains supplementary material, which is available to authorized users.