Clinical application of thrombelastogram and reference interval for our laboratory

Journal Title: Chinese Journal of Blood Transfusion - Year 2023, Vol 36, Issue 4

Abstract

Objective To respectively analyze the application of thrombogram (TEG) in our hospital and explore the reference interval for our laboratory. Methods Healthy adults who underwent physical examination in our hospital from November 2021 to October 2022 were selected, and their TEG indicators (R, K, Angle, MA, CI, G) were recorded and statistically analyzed to compare the difference in clinical application of our hospital between laboratory reference interval and the manufacturer interval. Results All main parameters of TEG correspond to normal distribution, with reference interval as R(3.77-7.97)min, K(1.02-2.70)min, Angle(54.37-73.35)°, MA(51.69-70.59)mm, CI(-2.73-+ 2.75), G(4.66-11.44) KPa. The TEG in our hospital exceeded the reference interval rate of the manufacturer and our laboratory: significant differences in R, K, Angle, CI and G were observed (P<0.05), but not in the MA (P>0.05). Meanwhile significant difference was noticed by gender (P<0.05). Conclusion There is significant difference between the reference interval of our laboratory and the manufacturer, and reference interval in our laboratory is more suitable for local patients. It is recommended that each laboratory establish reference interval scientifically to better guide clinical diagnosis and treatment.

Authors and Affiliations

Jiafu HUANG, Pengzhi WANG, Yaojian WU

Keywords

Related Articles

Research progress of IgM-enriched human intravenous immunoglobulin products

Comparing with conventional human intravenous immunoglobulin products (hIVIG), IgM-enriched hIVIG have more advantages in the neutralization of pathogens and related toxins, the regulation of complement activity, secreti...

Characteristics of donors in platelet bank of Taiyuan and application evaluation of the bank

Objective To establish the donor bank for local region and distinguish the donors based on the past blood donation frequency and blood donation type, so as to improve the application efficiency of platelet bank. Methods...

Determination of fibrinogen content in cryoprecipitated antihemophilic factor by fluorescence quenching method

Objective To establish a new method for the determination of fibrinogen content in cryoprecipitated antihemophilic factor. Methods Fibrinogen (Fib) could bind with sheep anti-human fibrinogen (anti-Fib) specifically and...

HBV infection among blood donors from 18 domestic blood stations of prefecture-level cities

Objective To analyze the hepatitis B virus (HBV) infection data of blood donors from 18 domestic blood stations, so as to investigate the HBV infection situation of blood donors. Methods The positive rate of HBV and its...

Blood immunological analysis of hemolytic disease of the fetus and newborn caused by Rh deletion type D--

Objective To analyze the causes of a case of hemolytic disease of the fetus and newborn (HDFN),and investigate the genetic background of maternal Rh deletion D--formation. Methods Blood samples of maternal and fetus were...

Download PDF file
  • EP ID EP738529
  • DOI 10.13303/j.cjbt.issn.1004-549x.2023.04.009
  • Views 3
  • Downloads 0

How To Cite

Jiafu HUANG, Pengzhi WANG, Yaojian WU (2023). Clinical application of thrombelastogram and reference interval for our laboratory. Chinese Journal of Blood Transfusion, 36(4), -. https://europub.co.uk/articles/-A-738529