Commissioning and validation of the electron Monte Carlo dose calculation at extended source to surface distance from a medical linear accelerator

Journal Title: International Journal of Medical Research and Review - Year 2016, Vol 4, Issue 7

Abstract

Introduction: Radiotherapy is one of the major modality for cancer management playing curative, adjuvant, and palliative and sometimes has an alternative role to chemotherapy. Radiotherapy is practiced in two ways viz. External beam therapy and Brachytherapy. Electron beam therapy is widely used in the management of cancers. An electron beam is characterized by a finite range of penetration with a rapid dose fall off towards a slowly decaying x-ray background as the electrons traverse through tissues. The electron monte carlo (eMC) dose calculation algorithm for eclipse treatment system has been introduced by Varian Medical systems. The algorithm is commissioned and validated by comparing percentage depth dose (PDD) and gamma index. Methods: Percentage depth dose curves were generated for all the energies for 4x4 cm2 and 10x10 cm2 field sizes. The depth of maximum dose (R100), therapeutic depth (R85), depth of 50% isodose (R50) and the relative surface (Ds) were compared with the measured and calculated PDD curves. Results: The eMC calculated fluence and measured fluence were compared for all the energies and cones at nominal source to surface distance and extended distances. For 4x4 cm2 field size the maximum shift in R100 was 5 mm, R85 was 1.9 mm, R50 was 0.9 mm and the variation in the relative surface (DS) was about 25Gamma analysis shows excellent agreements with greater than 98% of the pixels passing the gamma requirements. Conclusion: We have successfully commissioned and validated the electron monte carlo dose calculation at extended source to surface distance.

Authors and Affiliations

T. Arunkumar, C. Varatharaj, M. Ravikumar, K. M. Ganesh, S. Sathiyan, Shwetha B

Keywords

Related Articles

Blood stream infections with Candida species: a prospective study in a tertiary care center

Candidemia describes the presence of Candidaspecies in the blood [1,2]. Invasive Candidiasis embodies a variety of diseases including Candidemia, dissemi¬nated Candidiasis, meningitis, and endo-phthalmitis. Most common f...

High resolution computed tomography in the evaluation of interstitial lung diseases: Imaging perspective revisited with review of literature

Aims and Objectives: The study was designed with a broad objective of studying the imaging findings of the common interstitial lung diseases and to assess the severity of the disease and determine the reversibility capab...

Spinal tuberculosis: imaging features on MRI

Introduction: Spine is the most common site of skeletal tuberculosis.Radiographic manifestations of tuberculous spondylitis include intraosseous and paraspinal abscess formation, subligamentous spread of infection, verte...

Single stage substitution urethroplasty using buccal mucosa in the management of stricture urethra in balanitis xerotica obliterans (BXO)

Introduction: Urethral stricture is “narrowing of the caliber of the urethra caused by the presence of a scar consequent to infection, inflammation or injury". Urethral strictures are difficult to manage. BXO is more res...

Altered Fractionation Intensity Modulated Radiotherapy with concurrent chemotherapy in head and neck cancer : a feseability study

Purpose: To assess the loco regional response and toxicity of patients to concurrent chemo-radiation with 6 fractions/week using Intensity Modulated Radiotherapy in locally advanced head and neck cancers. (oropharynx and...

Download PDF file
  • EP ID EP230630
  • DOI 10.17511
  • Views 151
  • Downloads 0

How To Cite

T. Arunkumar, C. Varatharaj, M. Ravikumar, K. M. Ganesh, S. Sathiyan, Shwetha B (2016). Commissioning and validation of the electron Monte Carlo dose calculation at extended source to surface distance from a medical linear accelerator. International Journal of Medical Research and Review, 4(7), 1155-1163. https://europub.co.uk/articles/-A-230630