Abstract

Introduction: Radiotherapy is one of the major modality for cancer management playing curative, adjuvant, and palliative and sometimes has an alternative role to chemotherapy. Radiotherapy is practiced in two ways viz. External beam therapy and Brachytherapy. Electron beam therapy is widely used in the management of cancers. An electron beam is characterized by a finite range of penetration with a rapid dose fall off towards a slowly decaying x-ray background as the electrons traverse through tissues. The electron monte carlo (eMC) dose calculation algorithm for eclipse treatment system has been introduced by Varian Medical systems. The algorithm is commissioned and validated by comparing percentage depth dose (PDD) and gamma index. Methods: Percentage depth dose curves were generated for all the energies for 4x4 cm2 and 10x10 cm2 field sizes. The depth of maximum dose (R100), therapeutic depth (R85), depth of 50% isodose (R50) and the relative surface (Ds) were compared with the measured and calculated PDD curves. Results: The eMC calculated fluence and measured fluence were compared for all the energies and cones at nominal source to surface distance and extended distances. For 4x4 cm2 field size the maximum shift in R100 was 5 mm, R85 was 1.9 mm, R50 was 0.9 mm and the variation in the relative surface (DS) was about 25Gamma analysis shows excellent agreements with greater than 98% of the pixels passing the gamma requirements. Conclusion: We have successfully commissioned and validated the electron monte carlo dose calculation at extended source to surface distance.

Authors and Affiliations

T. Arunkumar, C. Varatharaj, M. Ravikumar, K. M. Ganesh, S. Sathiyan, Shwetha B

Keywords

Related Articles

A study of the pain score following TRUS guided prostate biopsy with and without periprostatic lignocaine infiltration

Introduction: Prostate cancer is one of the most common cancers in Western countries and is now increasing worldwide. Transrectal ultrasound guided prostate needle biopsy (TRUS) is the standard procedure to diagnose or e...

Retrospective analysis of HSG in primary infertility

Introduction: Hysterosalpingography used to be a common Radiological Investigation since long time for the investigation of infertility. In the current era of imaging HSG remains to be a choice of investigation for infer...

Quality of life of young male catheterized patients

Introduction: It is pointless to point out that, Per-urethral or Supra-pubic Catheter compromises the Quality of life (QoL) of young male patients. Our study is about the comparison of QoL status along with depression of...

Histopathological study of breast lesions

Abstract Objectives: To study the histopathological features of neoplastic and non neoplastic lesions of breast. To correlate the pathological findings with clinical parameters. Design and methods: We have studied total...

Immunocytochemical staining of cervical smears – A comparative study with routine cytology for confirmation of precancerous and cancerous lesions of cervix

Introduction: Carcinoma cervix is one of the leading causes of morbidity and mortality. The most effective method of screening is based on Pap smear study. However, Pap smear has relatively low sensitivity and irreducibl...

Download PDF file
  • EP ID EP230630
  • DOI 10.17511
  • Views 131
  • Downloads 0

How To Cite

T. Arunkumar, C. Varatharaj, M. Ravikumar, K. M. Ganesh, S. Sathiyan, Shwetha B (2016). Commissioning and validation of the electron Monte Carlo dose calculation at extended source to surface distance from a medical linear accelerator. International Journal of Medical Research and Review, 4(7), 1155-1163. https://europub.co.uk/articles/-A-230630