Commissioning of two different algorithms for stereotactic Radiosurgery M6 FI+ CyberKnife system

Journal Title: International Journal of Medical Research and Review - Year 2018, Vol 6, Issue 8

Abstract

Introduction: Cyber Knife M6 FI+ a very precise robotic stereotactic radiosurgery system which is capable of delivering very high radiation dose to the tumour while minimizing radiation exposure to normal organs and tissues. MultiPlan treatment planning system is used with the CyberKnife unit and the algorithms used for optimization are Ray-Tracing and Monte Carlo. Our CyberKnife M6 FI+ system commissioning is done as per the vendor recommendation and meeting the local regulatory guidelines. Materials and Methods: Clinical beam data measurement is carried out using Radiation Field Analyzer, Diode E, Pinpoint chamber, Semiflex ionization chamber and Unidose E Electrometer. FC-65 ionization chamber used in absolute dose calibration. The mechanical accuracy of the robot and image stability was verified using Radiochromic film (EBT3), E2E and Iris QA toolkits along with software. StereoPHAN is used for the patient-specific QA point dose measurement. Results: Tissue phantom ratio, Off-centre ratio, Output factor, Percentage depth dose, open beam profile and absolute dose calibration are done as per the protocols. E2E performed for two different modes- static and motion. Iris aperture size measured for all the field sizes. The patient-specific QA delivered for both algorithms. Discussion: Clinical beam data measurements are within ±1% of composite data set, overall standard deviation for Output Factors of the fixed and Iris collimators are 0.0026 and 0.0063. The absolute dose was calibrated to 1cGy per MU. E2E, Iris QA and Laser and radiation coincidence values are within the tolerance. Patient-specific QA point dose measurement variation for Ray-Tracing and Monte Carlo is 3% and 2%. Conclusion: These exercises are mandatory to achieve the accurate, precise and high quality of treatment which also includes patient safety.

Authors and Affiliations

Mageshraja Kannan, Jefy Ninan, Prasobh Chandrasenan, Subodh Chandra Pande, Aditya Gupta, Harpreet Kaur, Ajay Khatri

Keywords

Related Articles

Mifepristone as cervical ripening agent for Labour induction in women with Previous one Caesarean Section

Background and Objective: Induction of labour is a common obstetric intervention. Women with a prior caesarean delivery have an increased risk of uterine rupture particularly when labour is induced. In women with previou...

Contrast-enhanced ultrasound for the evaluation of hepatic artery occlusion after liver transplantation

Introduction: Vascular complications after liver transplantation remain a major threat to the survival of recipients.HAT is a major cause of graft loss and patient mortality, with an incidence between 3% to 8% in transpl...

Clinical features, visual outcome and association with systemic diseasein patients with episleritis and scleritis. A study of 50 eyes

Introduction: Episcleritis and scleritis are inflammatory disorders which can have an acute presentation and are frequently encountered by primary care practitioners.Episcleritis is a benign, self-limited disease that re...

A study on incidence and severity of acute renal failure and its association with parasite density in hospitalised patients with falciparum malaria

Aims of the study: To find out the incidence of acute renal failure in falciparum malaria and to correlate between the degree of parasitism at presentation with acute renal failure and its outcome in falciparum malaria.M...

Cardiogenic shock in Non-ST elevated AMI patients in a rural tertiary care hospital in Eastern India

Introduction:Acute Myocardial infarction is one of the leading causes of morbidity and mortality worldwide. Cardiogenic Shock is the leading cause of death in patients hospitalised for acute MI. Although there is substan...

Download PDF file
  • EP ID EP486773
  • DOI 10.17511/ijmrr.2018.i08.13.
  • Views 157
  • Downloads 0

How To Cite

Mageshraja Kannan, Jefy Ninan, Prasobh Chandrasenan, Subodh Chandra Pande, Aditya Gupta, Harpreet Kaur, Ajay Khatri (2018). Commissioning of two different algorithms for stereotactic Radiosurgery M6 FI+ CyberKnife system. International Journal of Medical Research and Review, 6(8), 477-486. https://europub.co.uk/articles/-A-486773