Common-Mode EMI Reduction in Switching Flyback Power Supply by Implementing Cancellation Method of Heat-Sink Capacitor

Journal Title: روش های هوشمند در صنعت برق - Year 2014, Vol 5, Issue 20

Abstract

Electromagnetic compatibility in switching power converters which are noise sources themselves, has a special importance. Electromagnetic interference (EMI) in the form of conducted or radiated reaches to sensitive sections and interferes with their operation. On the other, electromagnetic compatibility (EMC) standards causes another forces to reduce noise in switching converters. Major part of noise is due to the common-mode (CM) current passes through parasitic elements to the circuit ground (Earth). One of the important parasitic elements from the CM noise viewpoint is the switch heat-sink capacitor (common-mode capacitor). In this paper, a cancellation method of the heat-sink capacitor via a passive circuit is proposed in a 50W isolated flyback converter and is also modeled in OrCAD software. Also, experimental measurement results of the CM electromagnetic interference in regular and proposed flyback converter prototypes are presented to examine the modeling accuracy. Based on the experimental results, significant reduction of CM-EMI is verified after applying the cancellation method of the heat-sink capacitor.

Authors and Affiliations

Mohammad Rouholah Yazdani, Maryam Fazel

Keywords

Related Articles

Optimal Feature Space Selection in Detecting Epileptic Seizure based on Recurrent Quantification Analysis and Genetic Algorithm

Selecting optimal features based on nature of the phenomenon and high discriminant ability is very important in the data classification problems. Since it doesn't require any assumption about stationary condition and siz...

Adaptive Coordination of Fuse – Recloser in a Distribution System with High PV Penetration

Employment of photovoltaic (PV) distributed Generation in the distribution system, leads to improvement of network voltage profile and power quality. On the other hand, it cause miscoordination between fuses and recloser...

A Systematic Approach to Sensitivity Analysis of Fault Tolerant Systems in NMR Architecture

A fault tree illustrates the ways through which a system fails. It states different ways in which combination of faulty components result in an undesired event in the system. Being used in phases such as designing and ex...

Adaptive Dynamic Surface Control is designed for Twin Rotor unmanned helicopter in three-dimensional space

In this paper, the system control design problem twin rotors helicopters Unmanned Aerial Vehicles (UAV) in three dimensional space Without uncertainty based on the dynamic adaptive control is studied. the adaptive Dynami...

Neuro-adaptive control in beating heart surgery based on the viscoelastic tissue model

In this paper, the problem of 3D heart motion in beating heart surgery is resolved by proposing a parallel force-motion controller. Motion controller is designed based on neuro-adaptive approach to compensate 3D heart mo...

Download PDF file
  • EP ID EP328455
  • DOI -
  • Views 111
  • Downloads 0

How To Cite

Mohammad Rouholah Yazdani, Maryam Fazel (2014). Common-Mode EMI Reduction in Switching Flyback Power Supply by Implementing Cancellation Method of Heat-Sink Capacitor. روش های هوشمند در صنعت برق, 5(20), 75-83. https://europub.co.uk/articles/-A-328455