COMPARATIVE ANALYSIS IMAGE RESULTS OF PANCREAS IN PORTAL VEIN PHASE ON CT SCAN ABDOMEN CONTRAST WITHOUT AND WITH MINIMUM INTENSITY PROJECTION IN CT SCAN 64 SLICE

Journal Title: Journal of Vocational Health Studies - Year 2019, Vol 2, Issue 3

Abstract

Background: Minimum Intensity Projection is a post-proccesing technique on CT Scan that useful for showing structures with low Hounsfiled Unit (HU) values such as pancreas. To demonstrate the anatomy and pathology of the pancreatic organs, a contrast CT scan was performed on pancreatic phase but pancreatic phase was rarely used, so it was replaced by the portal venous phase, but this technique is still rarely used among the radiographers. Objective: This study aimed to prove the image of the portal venous pancreatic vein on contrast contrast CT scan by using minimum intensity projection (MinIP) on CT scan 64 slices will produce a more optimal image than without the minimum intensity projection (MinIP). Methods: This study is a retrospective study with an observational analytic method to assess differences of pancreatic image in contrasting contrast CT scans with and with MinIP reforms on CT 64 slice modalities Philips Briliance. 30 images as samples, with the criteria set by the researchers. The image will be post proccesing without and by using MinIP reformat. Image results will be evaluated by two radiologist, then the data obtained will be tabulated and processed using SPSS software version 17. Result: From this research obtained the result that MinIP reformat able to produce pancreas image more optimal than image without MinIP reformat on CT scan 64 slice and shows a significant difference. Overall assessment of the image has an improvement with the MinIP but for the homogeneity of pancreatic images decreased. Conclusions: There was a significant difference between pancreatic venous porta port results in contrasting CT scans of the abdomen without and with MinIP reformat.

Authors and Affiliations

Maria Ramandita, Lailatul Muqmiroh, Pramono Pramono

Keywords

Related Articles

COMPARISON BETWEEN REMOVABLE AND FIXED ORTHODONTIC RETAINERS

Background: There are two kinds of retainers: removable retainer and fixed retainer. Removable retainer is an orthodontic retainer which can be inserted and removed by the patient, whereas fixed retainer is bonded perman...

VARIATION OF FIXED TONGUE CRIB FOR CORRECTING TONGUE THRUSTING HABIT

Background: Tongue thrusting is a behavior pattern in which the tongue protrudes through the anterior incisors and pushes the anterior teeth at rest position, during speech or swallowing. This bad habit causes malocclusi...

MONOLIER (MONOPOLI 5R): INNOVATION OF MONOPOLY GAMES AS 5R LEARNING MEDIA FOR EARLY EDUCATION

Background: The understanding of 5R (Ringkas, Rapi, Resik, Rawat, and Rajin) is still low among the people. This is due to the lack of early education on the 5R concept. MONOLIER (Monopoly 5R) is an inovation of learning...

HYPERTENSION THERAPY USING ACUPUNCTURE AND HERBALS OF LEDS AND CARROTS

Background: Hypertension or high blood pressure is an increase in systolic blood pressure of more than 140 mmHg and diastolic blood pressure of more than 90 mmHg in two measurements with an interval of five minutes in re...

SCORING ANALYSIS OF THE RELATIONSHIP BETWEEN MAGNETIC RESONANCE IMAGING- ANXIETY QUESTIONNAIRE (MRI-AQ) WITH HEART RATE TO PATIENTS ANXIETY LEVEL AT LUMBOSACRAL MRI EXAMINATION

Background: Anxiety during MRI examination becomes a common constraint and can have a negative effect that is the quality of the resulting image due to the existence of motion artifacts until the failure of the examinati...

Download PDF file
  • EP ID EP595436
  • DOI 10.20473/jvhs.V2I3.2019.101-106
  • Views 211
  • Downloads 0

How To Cite

Maria Ramandita, Lailatul Muqmiroh, Pramono Pramono (2019). COMPARATIVE ANALYSIS IMAGE RESULTS OF PANCREAS IN PORTAL VEIN PHASE ON CT SCAN ABDOMEN CONTRAST WITHOUT AND WITH MINIMUM INTENSITY PROJECTION IN CT SCAN 64 SLICE. Journal of Vocational Health Studies, 2(3), 101-106. https://europub.co.uk/articles/-A-595436