Comparative analysis of colour change measurement devices in textile industry
Journal Title: Bulletin of the Military University of Technology - Year 2014, Vol 63, Issue 3
Abstract
In the paper there is presented a trial of application of new measurement principle of colour change with the use of DigiEye device. Comparison of DigiEye with commonly use in the textile industry spectrophotometer Macbeth 2020 was an aim of determination of relationship between parameters of both measurement systems. Samples for the colour change assessment on both measurement systems were first aged in the Xenotest 150. Ageing process was done according to the method of blues scale. Results were obtained by the colour measurement devices before and after the ageing test each releasing the diaphragms during exposing the examined samples on the light. Result of colour change were obtained in the colour system CIE L*a*b*. The measurements were done for PES fabrics destined on the outer layers of clothing. [b]Keywords[/b]: textiles, spectrophotometer, colorimeter [b][/b]
Authors and Affiliations
Paulina Gilewicz , Joanna Rutowicz , Iwona Frydrych, Agnieszka Cichocka
Protection against weapons of mass destruction. Technical and functional solutions for sub-units of the Territorial Defense Forces — collective protection
This material characterises the defense against weapons of mass destruction, as a system of security forces in case of risks of contamination (infections) in functional and performance-oriented terms. The basic technical...
Analiza wpływu losowego rozkładu luzów montażowych na ugięcia i nośność belek składanych
Artykuł obejmuje analizę wpływu losowego rozkładu luzów montażowych o różnych wielkościach na ugięcia i nośność belki składanej opartej na podporach stałych. Analiza ta zawiera siedem wariantów losowego występowania posz...
The safe use of building installations
The article describes the issues of technical solutions to contemporary installations used in modern buildings. Technical characteristics of installation systems refer to various sources of heat for building heating and...
The solution to the Lamb’s problem for nonlocal thermo-visco-elastic medium
In our work we constructed the solution of the initial-boundary value problem so-called Lamb’s problem for the half space occupied with thermo-visco-elastic medium. The visco-elastic medium was described by the Biot mode...
Analiza dokładności pomiarów nanometrycznych wzorców mikrogeometrii powierzchni za pomocą mikrointerferometru i profilometru stykowego
W pracy zostały zbadane i przeanalizowane możliwości pomiarowe Samodzielnego Laboratorium Długości GUM w obszarze pomiarów wzorców wysokości nierówności powierzchni (o wysokości nierówności poniżej 1 μm) — tzw. nanowzorc...