Comparative evaluation of accuracy of manual CCC using Patwardhan capsular marker and manual CCC without marker

Journal Title: Medpulse International Journal of Ophthalmology - Year 2017, Vol 1, Issue 2

Abstract

Modern cataract surgery aims at quality of vision with spectacle independence. Phacoemulsification surgery has already revolutionized the cataract surgery considering its small incision resulting into minimal surgically induced astigmatism. Since evolution of premier intraocular lenses (IOLs) like multifocal, toric and toric multifocal the exact placement of IOLs in the bag has become very crucial. This requires appropriate sized and well centred continuous curvilinear capsulorrhexis (CCC). Many techniques are available to create ideal CCC. Patwardhan CCC marker has been developed keeping in view economy and ease of use. This paper comparesaccuracy achieved in manual CCC using Patwardhan CCC marker and without using CCC marker.

Authors and Affiliations

Patwardhan Sourabh D, Joshi Ajit, Bhati Gaurav, Patwardhan Nidhi S

Keywords

Related Articles

Repeat DCR with silicon intubation tube

Purpose: To assess the efficacy of silicon tube intubation in repeat dacryocystorhinostomy procedure.Method: A prospective study in which 30 patients presenting with symptoms of watering or mucoid discharge 3 months afte...

The efficacy of Toric IOL in comparison to LRI in correcting pre-existing astigmatism in phacoemulsification

Background: With advances in cataract procedures and IOL technology, minimizing postoperative astigmatismis becoming increasingly important. Cataract surgery has become a “true refractive surgery” because of the meticulo...

Study of presentation and management outcome in patient with lens induced glaucoma

Purpose: To study presentation, intraocular pressure (IOP) control, visual prognosis and outcome of management in patients with lens induced glaucoma (LIG) Methods: Total 75 patients with LIG were included in the study....

Screening of school children for ocular defects: A cross sectional study

Background: Children are the wealth of a nation because tomorrow they will become its citizens and leaders. The economy and progress depends mainly on the younger generation. Hence they are to be nurtured to be the futur...

Comparative study of using fibrin glue and sutures in pterigyum excision with conjunctival autograft in tertiary care center

Background: Pterygium is a fibrovascular, wing shaped encroachment of the conjunctiva on to the cornea. The prevalence rates of pterygia range from 0.7 to 31% among different populations and are also influenced by age, r...

Download PDF file
  • EP ID EP213458
  • DOI -
  • Views 132
  • Downloads 0

How To Cite

Patwardhan Sourabh D, Joshi Ajit, Bhati Gaurav, Patwardhan Nidhi S (2017). Comparative evaluation of accuracy of manual CCC using Patwardhan capsular marker and manual CCC without marker. Medpulse International Journal of Ophthalmology, 1(2), 22-24. https://europub.co.uk/articles/-A-213458