Comparison of Energy Consumption in the Classical (PID) and Fuzzy Control of Foundry Resistance Furnace

Journal Title: Archiwum Odlewnictwa - Year 2012, Vol 12, Issue 3

Abstract

Foundry resistance furnaces are thermal devices with a relatively large time delay in their response to a change in power parameters. Commonly used in automation classical PID controllers do not meet the requirements of high-quality control. Developed in recent years, fuzzy control theory is increasingly being used in various branches of economy and industry. Fuzzy controllers allow to introduce new developments in control systems of foundry furnaces as well. Correctly selected fuzzy controller can significantly reduce energy consumption in a controlled thermal process of heating equipment. The article presents a comparison of energy consumption by control system of foundry resistance furnace, equipped with either a PID controller or fuzzy controller optimally chosen.

Authors and Affiliations

E. Ziółkowski, P. Śmierciak

Keywords

Related Articles

Influence of Blowing of Argon on the Cleanness of Steel

The mechanical properties of steel components are controlled by the chemical composition and mechanical treatment to which the steel is submitted. Non-metallic inclusions have a very high influence on the steel quality b...

Examples of material solutions in bimetallic layered castings

In paper is presented technology of bimetallic layered castings based on founding method of layer coating directly in cast process so-called method of mould cavity preparation. Prepared castings consist two fundamental p...

Predicting ADI mechanical properties

Ductile cast iron was quench-hardened with the isothermal transformation according to two alternatives. The first treatment alternative consisted in the austenitizing process at temperature t = 830, 860 i 900°C and anne...

Identification of temperature changes dynamics in selected castings as a contribution to performance life improvement

Parameters describing boundary conditions and dynamics of temperature changes during casting cooling in foundry moulds and the successive performance, especially as regards the massive cast elements, were discussed. Cons...

Effect of overheating degree on the solidification parameters of AlSi17CuNiMg silumin

Melting technology, especially the temperature of overheating and pouring above the liquidus point Tliq as well as the cooling rate, determine alloy macro - and microstructure, and hence also casting performance proper...

Download PDF file
  • EP ID EP72799
  • DOI 10.2478/v10266-012-0095-9
  • Views 107
  • Downloads 0

How To Cite

E. Ziółkowski, P. Śmierciak (2012). Comparison of Energy Consumption in the Classical (PID) and Fuzzy Control of Foundry Resistance Furnace. Archiwum Odlewnictwa, 12(3), 129-132. https://europub.co.uk/articles/-A-72799