Comparison of Icare Pro Tonometry and Icare One Tonometry Measurements in Healthy Eyes

Journal Title: TÜRK OFTALMOLOJİ DERGİSİ - Year 2019, Vol 49, Issue 3

Abstract

Objectives: To compare intraocular pressure (IOP) measurements obtained with the Icare Pro tonometer used in clinical practice, and the Icare One self-tonometer. Materials and Methods: Fifty-two eyes of 52 healthy, right-handed individuals with no prior intraocular surgery or ocular trauma, structural ocular pathology, or systemic disease were evaluated. IOP was first measured using the Icare Pro tonometer. The participants were then told how to use the Icare One tonometer and asked to measure their own IOP. The results were analyzed statistically using SPSS v.24. Results: Of the 52 healthy participants, 16 (30.7%) were male and 36 (69.3%) were female. Their mean age was 31.6±6.3 (23-47) years. Mean IOP measured with the Icare Pro was 17.10±6.2 (11.5-25.2) mmHg, and the mean self-measured IOP with Icare One was 14.01±3.4 (7-24) mmHg. When the two methods were compared using Levene’s t test, there was a significant mean difference of -3.08±0.6 (95% confidence interval: -4.39 -1.78; p<0.001). Conclusion: In this study, there was a significant difference between the IOP measurements we made using the Icare Pro and the participants’ self-measured IOP using the Icare One, with the latter being relatively lower. This may be related to the fact that the participants were unfamiliar with using the Icare One. Although the Icare One is a promising tool for glaucoma patients to self-monitor their IOP, further studies are needed.

Authors and Affiliations

Hüseyin Mayalı, Çağlar Sarıgül, Emin Kurt, Özcan Rasim Kayıkçıoğlu, Süleyman Sami İlker

Keywords

Related Articles

Posterior Polar Santral Koroidal Distrofi: Olgu Sunumu

Elli iki yaşında erkek hasta 25 yıldır az görme hikayesi ile başvurdu. En iyi düzeltilmiş görme keskinliği sağ gözde 0,3 sol gözde 0,2 düzeyindeydi. Fundus incelemesinde her iki gözde arka kutupta vasküler arkadlar arası...

Approach of Family Physicians to Pediatric Eye Screening in Diyarbakır

Objectives: In Turkey, preventive medicine services are the responsibility of family physicians and vision screening is a key component of this responsibility. In this study, we aimed to investigate the approach of famil...

Evaluation of Scheimpflug Tomography Parameters in Subclinical Keratoconus, Clinical Keratoconus and Normal Caucasian Eyes

Objectives: To evaluate tomographic and topographic parameters in subclinical and clinical keratoconus eyes by comparing them with normal eyes in a young Caucasian population. Materials and Methods: This cross-sectional...

Diyabetik Maküla Ödeminde Kortikosteroid Tedavisi

Diyabetik maküla ödemi diyabet hastalarında görme kaybının en sık nedenidir. Maküla ödeminin patogenezi karmaşık ve multifaktöriyeldir. Uzun yıllar lazer fotokoagülasyon tedavide standart olarak kabul edilmiştir, ancak a...

Uygulamada Selektif Lazer Trabeküloplastiye Karşı Timolol İçeren Fiks Kombinasyonlar: Primer Açık Açılı Glokomda Replasman Çalışması

Amaç: Bu çalışmada primer açık açılı glokomda 360˚ ve 180˚ selektif lazer trabeküloplasti (SLT) tedavisi seçeneklerinin 6 aylık süreçte etkinlik açısından timolol içeren fiks kombinasyonlarla (FK) değiştirilebilirliğinin...

Download PDF file
  • EP ID EP592638
  • DOI 10.4274/tjo.galenos.2018.06787
  • Views 95
  • Downloads 0

How To Cite

Hüseyin Mayalı, Çağlar Sarıgül, Emin Kurt, Özcan Rasim Kayıkçıoğlu, Süleyman Sami İlker (2019). Comparison of Icare Pro Tonometry and Icare One Tonometry Measurements in Healthy Eyes. TÜRK OFTALMOLOJİ DERGİSİ, 49(3), 130-133. https://europub.co.uk/articles/-A-592638