Comparison of isolated-check visual evoked potential and standard automated perimetry in early glaucoma and high-risk ocular hypertension

Journal Title: International Journal of Ophthalmology - Year 2017, Vol 10, Issue 4

Abstract

"AIM: To compare the diagnostic performance of isolated-check visual evoked potential (icVEP) and standard automated perimetry (SAP), for evaluating the application values of icVEP in the detection of early glaucoma. METHODS: Totally 144 subjects (288 eyes) were enrolled in this study. icVEP testing was performed with the Neucodia visual electrophysiological diagnostic system. A 15% positive-contrast (bright) condition pattern was used in this device to differentiate between glaucoma patients and healthy control subjects. Signal-to-noise ratios (SNR) were derived based on a multivariate statistic. The eyes were judged as abnormal if the test yielded an SNR≤1. SAP testing was performed with the Humphrey Field Analyzer II. The visual fields were deemed as abnormality if the glaucoma hemifield test results outside normal limits; or the pattern standard deviation with P<0.05; or the cluster of three or more non-edge points on the pattern deviation plot in a single hemifield with P<0.05, one of which must have a P<0.01. Disc photographs were graded as either glaucomatous optic neuropathy or normal by two experts who were masked to all other patient information. Moorfields regression analysis (MRA) used as a separate diagnostic classification was performed by Heidelberg retina tomograph (HRT). RESULTS: When the disc photograph grader was used as diagnostic standard, the sensitivity for SAP and icVEP was 32.3% and 38.5% respectively and specificity was 82.3% and 77.8% respectively. When the MRA Classifier was used as the diagnostic standard, the sensitivity for SAP and icVEP was 48.6% and 51.4% respectively and specificity was 84.1% and 78.0% respectively. When the combined structural assessment was used as the diagnostic standard, the sensitivity for SAP and icVEP was 59.2% and 53.1% respectively and specificity was 84.2% and 84.6% respectivlely. There was no statistical significance between the sensitivity or specificity of SAP and icVEP, regardless of which diagnostic standard was based on. CONCLUSION: The diagnostic performance of icVEP is not better than that of SAP in the detection of early glaucoma."

Authors and Affiliations

Ying-Xi Zhao

Keywords

Related Articles

Comparison of surgical outcome of trabeculectomy and phacotrabeculectomy in Chinese glaucoma patients

Our study retrospectively reviewed the surgical outcomes up to 3mo of 38 consecutive Chinese glaucoma patients who underwent trabeculectomy (n=18) or phacotrabeculectomy (n=20). Baseline age, visual acuity, and intraocul...

The prognostic value of lymphocyte-to-monocyte ratio in retinopathy of prematurity

"AIM: To evaluate the associations between development of retinopathy of prematurity (ROP) and serum lymphocyte-to-monocyte ratio (LMR), neutrophil-to-lymphocyte ratio (NLR), and platelet-to-lymphocyte ratio (PLR). METHO...

ipRGCs: possible causation accounts for the higher prevalence of sleep disorders in glaucoma patients

Sleep accounts for a third of one’s lifetime, partial or complete deprivation of sleep could elicit sever disorders of body function. Previous studies have reported the higher prevalence of sleep disorders in glaucoma pa...

Optical coherence tomography angiography of optic disc perfusion in non-arteritic anterior ischemic optic neuropathy

"AIM: To compare the optic disc blood flow of non-arteritic ischemic optic neuropathy (NAION) eyes with normal eyes. METHODS: The optic disc blood flow densities of diagnosed non-acute phase NAION eyes (21 eyes, 14 indiv...

Download PDF file
  • EP ID EP605171
  • DOI 10.18240/ijo.2017.04.16
  • Views 54
  • Downloads 0

How To Cite

Ying-Xi Zhao (2017). Comparison of isolated-check visual evoked potential and standard automated perimetry in early glaucoma and high-risk ocular hypertension. International Journal of Ophthalmology, 10(4), -. https://europub.co.uk/articles/-A-605171