COMPARISON OF OCULAR BIOMETRYAND CORNEAL CURVATUREAMONG MALAYSIAN EMMETROPES AND MYOPES

Journal Title: Indian Journal of Scientific Research - Year 2015, Vol 6, Issue 1

Abstract

A cross sectional study was conducted by including 47 Malaysian subjects aged 18-35 years. The purpose is to find out the variations in ocular biometry according to refractive state and rule out the most contributing factor for the degree of myopia among Malaysia subjects. Keratometer and A-scan ultrasonography were used to measure the corneal curvature and biometric parameters respectively. Comparison of ocular components for gender and onset of myopia were done by using independent t-test. One way ANOVA was done to compare biometric parameters with refractive states. Comparison of the axial length (p=0.49), anterior chamber depth (p=0.28), lens thickness (p=0.06) and cornea radius (p=0.94) showed no significant difference based on age groups and gender. Lens thickness (p<0.05) showed significant difference based on onset of myopia Refractive state has a significant relation to axial length (p<0.001), lens thickness (p=0.03), corneal radius (p<0.001) and AL/CR ratio (p<0.001). Axial length was having more effect on high myopia group whereas corneal radius and AL/CR ratio showed more effect on emmetropia group. There was a significant difference in biometric parameter, corneal curvature and AL/CR ratio between emmetropia and myopia except anterior chamber depth. In addition, there was a significant difference in lens thickness exits based on the onset of myopia. Axial length was the main morphological factor related to myopia. AL/CR ratio is a better index for categorizing the refractive status of an individual than axial length alone

Authors and Affiliations

CHIRANJIB MAJUMDER

Keywords

Related Articles

Dose Response Study of N, N’-Dimethylurea (DMU) Antidote Total Foliar Protein in Lycopersicon esculentum. Against the Effect of O3

To overcome the problem of agriculture loss due to air pollution, an alternative method would involve the application of protective chemical components to plants in the field to prevent injury. The studies of the potenti...

ANALYSIS & ESTIMATION OF EM ENERGY COUPLING TO THE UNDERGROUND STRUCTURES USING COMPUTATIONAL METHOD

In case of the large underground structures the Electro-Magnetic Compatibility, necessarily susceptibility, with respect to the external electromagnetic sources is very important as the vital equipment used inside these...

KNOWLEDGE OF PREGNANT WOMENABOUT DANGER SIGNS IN NEWBORNS REQUIRING MEDICAL CONSULTATION IN PERIURBAN AREA OFALIGARH

To assess the knowledge of pregnant women regarding danger signs in newborns requiring medical consultation. Study design: A community based study. Setting: Field practices areas of Urban Health Training Center Departmen...

TO EVALUATION OF OF UTERINE ARTERIAL BLOOD FLOW IN EARLY PREGNANCY IN WOMEN WITH RECURRENT PREGNANCY LOSS

A prospective observational study for evaluation of blood flow resistance in uterine arteries was conducted from March 2012 to April 2013. Around 120 pregnant women at 5 to 9 weeks gestation included and underwent transv...

ESTIMATION OFANTI-NUTRITIONAL PROPERTIES IN PULSESAND THEIR MITIGATION USING VARIOUSPROCESSINGMETHODS

An experimental study was conducted to study the possible processing methods that can be used for the reduction of anti-nutritional factors from six commonly used pulses in India. The six selected pulses were Biri(Black...

Download PDF file
  • EP ID EP368200
  • DOI -
  • Views 82
  • Downloads 0

How To Cite

CHIRANJIB MAJUMDER (2015). COMPARISON OF OCULAR BIOMETRYAND CORNEAL CURVATUREAMONG MALAYSIAN EMMETROPES AND MYOPES. Indian Journal of Scientific Research, 6(1), 1-9. https://europub.co.uk/articles/-A-368200