Comparison of the Efficacy of Digital Caliper and a Newly Designed Digital Bone Gauge for Measurement of Edentulous Alveolar Ridge Width

Abstract

Objectives: An efficient, safe, affordable and easily accessible measuring instrument for quantitative assessment of bone prior to dental implant placement enables more accurate treatment planning. Costly imaging modalities are neither widely available, nor affordable for some patients. This study sought to assess the efficacy of a newly designed digital bone gauge for measurement of bone width with 0.1 mm accuracy in comparison with a digital caliper. Methods: Using CATIA software, three-dimensional (3D) model of the instrument was designed and its experimental version was fabricated in two models and tested on an edentulous alveolar ridge model. The efficacy of the instrument was assessed by comparing the values obtained by the designed bone gauge with direct measurements made by a digital caliper. The buccolingual width of the edentulous ridge was measured at the crestal level and at 1, 2, 3 and 4 mm apical to the bone crest by the designed bone gauge and digital caliper. The intraclass correlation coefficient (ICC) of the values was calculated. Results: Virtual and experimental models of the instrument were designed and patented. The designed instrument was successfully capable of measuring bone width with 0.1 mm accuracy. The ICC values at 1, 2, 3 and 4 mm apical to the bone crest and at all levels were calculated to be 0.973, 0.994, 0.997, 0.998 and 0.998, respectively. Conclusion: The designed digital bone gauge can efficiently measure bone width at different levels with high accuracy. It can provide valuable and reliable information about bone width at initial clinical examination.

Authors and Affiliations

Reza Amid, Kasra Rahimipour, Mahshid Namdari, Mahdi Kadkhodazadeh

Keywords

Related Articles

Titanium Implant Osseointegration in Rheumatoid Arthritis Patients: Report of Two Cases

Objectives Dental implant rehabilitation in patients suffering from rheumatoid arthritis (RA) has been reported to improve the quality of life. Implant treatment success depends on many factors such as appropriate osseoi...

Accuracy and characteristics of cephalometric software programs for outcome prediction of orthognathic treatments: A review

Objectives: Several software programs have been designed for outcome prediction of orthodontic and surgical treatments. This study aimed to review the accuracy and characteristics of cephalometric software programs for o...

In Vitro Effect of Hydroalcoholic Extract of Aloe Vera and 0.2% Chlorhexidine Mouthwash on Streptococcus Sanguinis, Streptococcus Salivarius and Streptococcus Mutans

Objectives This study aimed to assess the antimicrobial effects of aloe vera hydroalcoholic extract and 0.2% chlorhexidine (CHX) mouthwash on Streptococcus sanguinis (S. sanguinis), Streptococcus salivarius (S. salivariu...

Effect of Awareness and Reassurance on Anxiety of Dental Implant Candidates

Objectives: Dental anxiety can be potentially problematic. Anxiety must be controlled in highly anxious patients in order to ensure a smooth procedure and prevent potential complications. Awareness and reassurance are be...

Crazing Level after Pin Insertion in Anterior Primary Teeth: A Preliminary In Vitro Study

Objectives: This study aimed to investigate dentinal crack rate following parapulpal pin insertion in anterior primary teeth. Methods: Thirteen sound freshly extracted primary canine teeth were horizontally sectioned 1 m...

Download PDF file
  • EP ID EP368322
  • DOI -
  • Views 61
  • Downloads 0

How To Cite

Reza Amid, Kasra Rahimipour, Mahshid Namdari, Mahdi Kadkhodazadeh (2017). Comparison of the Efficacy of Digital Caliper and a Newly Designed Digital Bone Gauge for Measurement of Edentulous Alveolar Ridge Width. Journal of Dental School Shahid Beheshti University of Medical Sciences, 35(3), 76-80. https://europub.co.uk/articles/-A-368322