Computerized Tomographic Morphometric Study Of Last Thoracic And All Lumbar Pedicles In The Indian Population Related To Pedicle Screw Fixation

Abstract

Transpedicular fixation of the spine with pedicular screws is becoming increasingly popular being more stable and versatile as it provides three dimensional fixations. Several systems of internal fixation that uses the pedicle as a source of purchase for bone screws from posterior approach into the vertebral body are currently available .A data was collected by CT scan measurement of the pedicles along with 8 of its parameters and were compare with other associated studies with a collection of a mixed group of 80 patients .This data were then used to verify the accuracy of the technique that radiologist and surgeons must used for preoperative of evolution .This study indicates that computer software were aided pedicular morphometric data are reliable and comparable to other published study with other methods. For the Indian population the diameter and length of the pedicle screw need to be smaller than those mentioned in western studies. Therefore the need of CT morphometric data assessment preoperative planning of spinal surgery at different spinal level is important in account of large variation so that intra and postoperative complication can be avoided.

Authors and Affiliations

Salim A Lad, Pradip B Patil, P V Naveen kumar, Rajesh Bhadu, Nikhil Bothara, Ravindra S Patil

Keywords

Related Articles

The Management Of Distal End Radius Fractures In Adults

This document is intended towards the study of different types of fractures of distal end radius in adults, their management with different modalities of treatment. AO classification for distal end radius fractu...

Comparison Of Haemodynamic Effects Of Atropine And Glycopyrrolate

Atropine and glycopyyrolate a quaternary ammonium drug were evaluated in 34 patients following intramuscular administration on the basis of haemodynamic effects. Gycopyrrolate appears to be 5 times more potent than in...

Retrograde Enders Nail –An Excellent Option For Tibial Shaft Fractures With Compound Wound Over And Around The Knee

Aims & Objectives: A mode of treatment using retrograde enders nailing for compound (Gustillo- Anderson type 2 and type 3A) tibial shaft fractures with wound over and around the knee where intermedullary nailing is not p...

Evaluation Of Ultrasound And CT Findings In Conjunction With Its Comparison In Pancreatitis And Its Complications

OBJECTIVE- The study aims to evaluate the spectrum of findings and compare the role of ultrasonography (US) and CECT in evaluation of pancreatitis and its complications. MATERIALS AND METHODS: Fifty patients with clinica...

Comparative Study On Functional Outcome Of Steroid Injection Vs Conservative Management In Plantar Fascitiis

Aim: Plantar fasciitis is the most common cause of inferior heel pain. Steroid injections have been described to treat plantar heel pain since many years. The need for this study is to evaluate the functional outcome fol...

Download PDF file
  • EP ID EP394694
  • DOI -
  • Views 137
  • Downloads 0

How To Cite

Salim A Lad, Pradip B Patil, P V Naveen kumar, Rajesh Bhadu, Nikhil Bothara, Ravindra S Patil (2016). Computerized Tomographic Morphometric Study Of Last Thoracic And All Lumbar Pedicles In The Indian Population Related To Pedicle Screw Fixation. International Journal of Orthopaedics Traumatology & Surgical Sciences, 2(2), 304-309. https://europub.co.uk/articles/-A-394694