Condition Assessment and Rating of a Building using Condition Survey Protocol (CSP) 1 Matrix

Journal Title: GRD Journal for Engineering - Year 2019, Vol 4, Issue 0

Abstract

Purpose - This study aims to provide assessment method for building’s condition. Building inspection is one of the key component of building maintenance as it is used for evaluating building’s current condition. Traditionally, a longhand survey description has been used for condition report. Survey that employ ratings instead of description are gaining acceptance in the industry. Hence this study provides quantitative approach towards assessing buildings condition which can be used for defining maintenance plan and also presents a case study carried out. Methodology - In this study, we adopted a condition survey protocol (CSP) 1 matrix for assessment of building’s condition. Two types of ratings are condition assessment and priority assessment. These two assessment criteria are then multiplied to find out the final score of the defects. Findings - The full score is used to give the building an overall rating: good, fair or dilapidated and according to the score type of maintenance can be suggested for the building. Originality/value – The computerized tool can be used for condition assessment, providing an overall rating to the building and type of maintenance needed.

Authors and Affiliations

Lavingiya Raag, Qureshi Sulaim, Solanki Parth

Keywords

Related Articles

Novel Scheduling Policy for Delay Analysis of Multi-Hop Wireless Networks

To maximizes the throughput performance of the systems, the scheduling algorithm which is widely used in multi-hop wireless networks and high speed switches need wide range of study. Various studies have subsequently foc...

Design of Metamaterial Antenna For Wireless Applications

A multiband compact planar antenna was designed with frequency notched function, the antenna with CPW fed is consist of various microstrip resonators, such as closed ring resonator and SRR, producing some discontinuous r...

Autoclaved Aerated Concrete: A Sustainable Alternate of Clay Brick Masonry in Form of Light Weight Concrete

This type of lightweight concrete has no coarse aggregates in its mixture, and it can be mentioned that aerated lightweight concrete is the concrete mortar which is aerated with gas injection and also can be aerated by u...

A Detailed Study On Car-Free City And Conversion Of Existing Cities And Suburbs To The Car-Free Model

Manufacture and use of cars are increasing day by day. This is creating environmental, social and aesthetic issues that we never imagined in last few decades. These problems force urban planners to think and design the c...

Design of MPPT for Wind Power System

Wind energy, even though abundant, varies continually as wind velocity varies in magnitude and direction over a time period. As the wind turbine’s rotation depends upon the availability of wind force and if the wind turb...

Download PDF file
  • EP ID EP550912
  • DOI -
  • Views 126
  • Downloads 0

How To Cite

Lavingiya Raag, Qureshi Sulaim, Solanki Parth (2019). Condition Assessment and Rating of a Building using Condition Survey Protocol (CSP) 1 Matrix. GRD Journal for Engineering, 4(0), 1-6. https://europub.co.uk/articles/-A-550912