CONNECTION CAPACITY OF THE TRANSITION ZONE IN STEEL-CONCRETE HYBRID BEAM

Journal Title: Civil and Environmental Engineering Reports - Year 2017, Vol 2, Issue 25

Abstract

The problem of transition zone of structural steel element connected to concrete is discussed in the following paper. This zone may be located for instance in specific bridge composite girder. In such case the composite beam passes smoothly into concrete beam. Because of several dowels usage in the transition zone, the problem of uneven force distribution were discussed through analogy to bolted and welded connections. The authors present innovative solution of transition zone and discuss the results, with emphasis put on the transition zone structural response in term of bending capacity, failure model and force distribution on the connection length. The article wider the already executed experimental test and presents its newest results.

Authors and Affiliations

Piotr KOZIOŁ, Maciej KOŻUCH, Wojciech LORENC, Sławomir ROWIŃSKI

Keywords

Related Articles

STRESS EQUATIONS FOR ADHESIVE IN TWODIMENSIONAL ADHESIVELY BONDED JOINTS

The subject of this paper is formulation of shear stress equations for plane twodimensional adhesive layers present in adhesively bonded joints. The adherends are assumed to have the same thickness and be made of an isot...

Infection of scots pine afforestations (Pinus sylvestris L.) by annosum root rot (Heterobasidion annosum (fr.) Bref.) in the eastern german lignite district

During the last years an alarming dieback has occurred in 20 to 40 years old first-rotation pine stands (Pinus sylvestris L.) on mine sites, caused by the white rot fungus Heterobasidion annosum (Fr.) Bref. First thinnin...

THE PROBLEM OF ADAPTING EXISTING RESIDENTIAL BUILDINGS IN THE COUNTRY TO THE REQUIREMENTS OF ECOLOGY

The article presents the results of direct research on residential buildings and their modernization in selected ecological farms of the Mazovia region. The research area covered two poviats (counties) in the Mazowieckie...

Polycyclic aromatic hydrocarbons (PAH) in gravity-operated and surface water from areas located nearby coking plant in Dąbrowa Górnicza (Upper Silesia region, Poland)

The paper presents the results of five PAHs contents determination in the surface and gravity-operated water. The samples of gravity-operated water were taken quarterly in 2009 from collectors put in fifteen points in ar...

Application of fundamental solutions to the static analysis of thin plates subjected to transverse and in-plane loading

In this paper static analysis of Kirchhoff plates is considered. A transverse and in-plane loading is taken into consideration. The Finite Strip Method is used and the suitable fundamental solutions are applied. Accordin...

Download PDF file
  • EP ID EP243264
  • DOI -
  • Views 82
  • Downloads 0

How To Cite

Piotr KOZIOŁ, Maciej KOŻUCH, Wojciech LORENC, Sławomir ROWIŃSKI (2017). CONNECTION CAPACITY OF THE TRANSITION ZONE IN STEEL-CONCRETE HYBRID BEAM. Civil and Environmental Engineering Reports, 2(25), 137-146. https://europub.co.uk/articles/-A-243264