Abstract

The paper is based on a study for the diagnosis of power transformer through the signal configuration that are part of the clock hour figure code for a defect transformer. The investigations made have the purpose to compare the code signal before and after the transformers damage. The comparative analyzes of the signal form, course and polarity are constituted in diagnosis criteria and are formulated the conclusion about the defect location, nature and dimension.

Authors and Affiliations

Cristina Prodan, Mihaela Poienar, Ovidiu-Magdin Ţanţa, Adrian-Neculai Romanescu, Daniel Ștefan Georgescu, Dorel Cernomazu

Keywords

Related Articles

Efficiency Investigation on a Helical Gear Transmission​

Gears are extensively used in many applications, such as: automotive, drive trains, industrial gearboxes and machine tools. They are designed to transmit power and rotational motion from the input shaft to the output sha...

Experimental Measurements of Adherence of Thermally​ Sprayed Layers

The bond strength of the thermally sprayed coatings is one of the most important features in the assessment of deposition quality. Standardized methods for determining the adhesion of thermally sprayed coatings refer to...

Harmonics Study of Common Low Wattage LED Lamps

This article presents experimental data on Light Emitting Diode (LED) lamps of low wattage that are commonly found both in commercial and residential applications. A comparison with the existing regulations is performed....

Contributions to Design of Actuators functioning with Nitinol Active Springs

The paper presents the research results achieved in order to perform a comparison regarding the influence of natural and forced cooling proc-ess applied to the Nitinol active springs inside a linear motion actuator. SMAs...

A Solution to Study Different Homing Methods Using a PLC

In a positioning control with stepper motors it is very important to know zero location. For this purpose it is necessary a homing command. This paper presents a solution that allows the study of different methods...

Download PDF file
  • EP ID EP460831
  • DOI -
  • Views 93
  • Downloads 0

How To Cite

Cristina Prodan, Mihaela Poienar, Ovidiu-Magdin Ţanţa, Adrian-Neculai Romanescu, Daniel Ștefan Georgescu, Dorel Cernomazu (2014). Contributions Concerning the Clock Hour Figure Utilization for the Power Transformer Diagnostic. Analele Universitatii "Eftimie Murgu" Resita. Fascicula de Inginerie, 21(2), 145-156. https://europub.co.uk/articles/-A-460831