Correction of Class 2 malocclusion by means of a fully adjustable, virtually unbreakable, mandibular positioning (jumping) device
Journal Title: Journal of Stomatology (Czasopismo Stomatologiczne) - Year 2015, Vol 68, Issue 3
Abstract
Introduction. The construction and adaptation of the appliance to the individual patient is described and illustrated. The aim of the present report is to describe the development and clinical testing of an adjustable, unbreakable “bite-jumping” device, the “Flex Developer”® incorporating a nylon rod as the extendable “bite-jumping” element. Material and method. The report describes clinical testing on two groups of patients (young N = 17, mature N = 12) using a cephalometric appraisal before and after treatment. Results. The efficiency of the appliance in correcting Class II malocclusion by means a series of skeletal and dento-alveolar changes is clearly illustrated, the statistically significant skeletal improvement being greater in the younger (under 19 years) patients. Conclusion. The appliance constitutes a reliable adjunct to orthodontic correction of the Class II anomaly.
Authors and Affiliations
Ivan Prystupa, Stephen Williams, Bartłomiej W. Loster
Bezpieczeństwo amalgamatu stomatologicznego Przyjęte przez Światowe Towarzystwo Stomatologiczne: 26 października 2007r. Dubaj, Zjednoczone Emiraty Arabskie
-<br/><br/>
Zasady leczenia pacjentów bezzębnych z zastosowaniem protez overdenture na implantach w żuchwie
Wprowadzenie. Leczenie protetyczne pacjentów bezzębnych często wiąże się z osobami uskarżającymi się na słabe utrzymanie protez całkowitych dolnych. W pracy przedstawiono zasady postępowania z takimi pacjentami, począwsz...
Survey of studies of stigmatization and discrimination of patients with HIV/AIDS by medical personnel – comparison of Polish experience with the global situation
Introduction. Since the emergence of the problem of HIV/AIDS infection, its pejorative social perception has been observed. The results of studies indicate occurrence of stigmatization and discrimination of patients with...
Research methodology, description of action and the application of Laser Doppler flowmeter to dentistry
Introduction. Laser Doppler Flowmetry (LDF) is a non-invasive method of assessing blood flow in the vascular bed in real time, which has a wide range of applications to medicine and dentistry. The device uses the Doppler...
Materiały stosowane w technologii CAD/CAM - przegląd piśmiennictwa
Technologia CAD/CAM pozwala wykonywać uzupełnienia protetyczne podczas jednej wizyty. Materiały, z których wykonuje się uzupełnienia to bloczki ceramiki szpatu polnego, ceramik wzmacnianych leucytem lub dwukrzemianem...