Cyclopentane. Determining cyclopentane in workplace air with gas chromatography with mass detection (GC-MS)

Journal Title: Podstawy i Metody Oceny Środowiska Pracy - Year 2014, Vol 30, Issue 1

Abstract

A new procedure has been developed for the assay of cyclopentane using gas chromatog-raphy with mass detection. The method is based on the adsorption of cyclopentane on activated charcoal and desorption with carbon disulfide. The resulted solutions are analysed with gas chromatography with mass detection. The working range of the analytical method is 150 ÷ 5000 µg/ml (300 ÷ 10000 mg/m3 for a 0.5- L air sample and 30 ÷ 1000 mg/m[sup]3[/sup] for a 5-L air sample). Limit of quantification: 131.2 µg/ml. The developed method of determining cyclopentane has been recorded as an analytical procedure (see Appendix).

Authors and Affiliations

Małgorzata Kucharska, Wiktor Wesołowski, Jan Gromiec

Keywords

Related Articles

Cisplatyna. Dokumentacja proponowanych dopuszczalnych wielkości narażenia zawodowego

Cisplatyna jest cytostatykiem stosowanym w terapii raka: jądra, jajnika, pęcherza moczowego, kolczystokomórkowego głowy i szyi, drobnokomórkowego i niedrobnokomórkowego płuca oraz szyjki macicy. Dla personelu medycznego...

Narażenie na hałas o częstotliwości 10 ÷ 40 kHz na stanowiskach pracy zgrzewarek ultradźwiękowych – techniczne sposoby ograniczenia narażenia

W artykule przedstawiono wyniki narażenia na hałas o częstotliwości 10 ÷ 40 kHz na wybranych stanowiskach pracy zgrzewarek ultradźwiękowych. W przypadku dwóch stanowisk pracy zamieszczono przykłady ograniczenia emisji ha...

Doxorubicin hydrochloride. Determination in workplace air with high performance liquid chromatography

This article presents a method for measuring doxorubicin hydrochloride in workplace air with HPLC with diode array detector (DAD). The method is based on adsorption inhalable fraction of doxorubicin hydrochloride aerosol...

The activity of the Interdepartmental Commission for Maximum Admissible Concentrations and Intensities for Agents Harmful to Health in the Working Environment in 2017 and the work plan in 2018

In 2017, the Commission met at three sessions, in which 16 documentations for recommended exposure limits of chemical substances were discussed. Moreover, the Commission discussed: − the positions of the Interdepartment...

Sprawozdanie z działalności Międzyresortowej Komisji ds. Najwyższych Dopuszczalnych Stężeń i Natężeń Czynników Szkodliwych dla Zdrowia w Środowisku Pracy w latach 2011-2013

W ramach II etapu programu wieloletniego „Poprawa bezpieczeństwa i warunków pracy” w latach 2011-2013 odbyło się 9 posiedzeń Komisji, na których rozpatrywano: 31 dokumentacji wartości dopuszczalnych poziomów narażenia z...

Download PDF file
  • EP ID EP224578
  • DOI -
  • Views 98
  • Downloads 0

How To Cite

Małgorzata Kucharska, Wiktor Wesołowski, Jan Gromiec (2014). Cyclopentane. Determining cyclopentane in workplace air with gas chromatography with mass detection (GC-MS). Podstawy i Metody Oceny Środowiska Pracy, 30(1), 69-82. https://europub.co.uk/articles/-A-224578