Decimation Filter Design Optimization of ADC for ECG Processing

Abstract

Digital processing of ECG for arrhythmia analysis is very much dependent upon the ECG sapling resolution. However, over sampling may increase the processing cose and under sampling may introduce error in the analysis as vital information may be lost due to under sampling. Therefore, an optimized sampling is very much required for accurate arrhythmia analysis. There is a trade off between sampling rate and accuracy in analysis. However, an optimum solution may be achieved using the descimation filter in analog to digital conversion. The existing decimation filters in ADC suffers from the drawback of high sampling even for a constant signal due to very instant nature of the input signal. However, the sampling rate may be varied if a dynamic window is used to gate the input signal and then analog to digital conversion is performed. This enhances the maximum utilization of available bandwidth of the input signal. Index Terms: ADC, ECG, Decimation Filter

Authors and Affiliations

Sidharth Sarswat, Maninder Kaur

Keywords

.

Related Articles

Impact of Distributed Generation from Solar Energy on Power System Distribution in Nigeria

Distributed generation (DG) are electrical power generations designed at the customer load site. They have the ability to reduce technical losses, improve voltage profile and power quality. When adequately installed, it...

Portable Fire Detector

This paper describes the design of a portable fire detector which can easily detect the sudden rate of change of temperature and sound an alarm if preset value are exceeded. The detector is said to be portable because it...

The State Of Cloud Computing In Nigeria

This work provides lucid explanation of cloud computing, it's components and characteristics. It provides a detailed account of the history of cloud computing and the extent it has been adopted in Africa amidst the econo...

Comparison of Control Methods for Power Quality Improvement Using Dynamic Voltage Restorer and Hybrid Active Power Filter

Power quality is the most common factor which is looked by both power consumers and power suppliers. The power industry has to supply power to the consumers at rated magnitude and frequency and also uninterrupted. But du...

Mathematical Modelling And Steady-State Simulation Study of Three Phase Squirrel Cage Induction Machine, Using The Dot Convention Technique for Magnetically Coupled Circuit.

This paper presents the mathematical modelling and simulation study of three phase squirrel cage induction machine. This is achieved, using the dot convention technique for magnetically coupled circuit applicable to circ...

Download PDF file
  • EP ID EP388725
  • DOI 10.9790/1676-1302036366.
  • Views 128
  • Downloads 0

How To Cite

Sidharth Sarswat, Maninder Kaur (2018). Decimation Filter Design Optimization of ADC for ECG Processing. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 13(2), 63-66. https://europub.co.uk/articles/-A-388725