Design and Analysis of Total Elbow Replacement Joint

Abstract

The total elbow replacement joint is a surgical process of to replace the human arm joint into artificial joint. In this paper to present the investigation of various materials used like copper, stainless steel, titanium and cobalt chromium alloys in the total elbow replacement joint. Based on this paper the numerical simulation technique gives the comprehensive results for implantation of the device. The model was created in the Creo parametric by changing existing design and materials based on under design condition, then analysis was done. The various results were found like von mises stress, maximum principal stress during analysis and these results was compared to the good literature. After simulation, it was concluded that the cobalt chromium alloy based proposed design, which was gives the minimum stress and total mass of modal.

Authors and Affiliations

Vikky Kumhar, Amit Sarda

Keywords

Related Articles

Big Data and Big Data Management (BDM) with current Technologies –Review

The emerging phenomenon called ―Big Data‖ is pushing numerous changes in businesses and several other organizations, Domains, Fields, areas etc. Many of them are struggling just to manage the massive data sets. Big data...

Spectral correction for attenuating retroactivity in synthetic biology networks

The reliability of synthetic biology systems is challenged by the undesired retroactive signals transmitted by the downstream modules to the upstream modules. These retroactive signals modify the input and output signals...

Study on the Influence of the Shape of Leaf Spring on the Stress and the Kinematic Characteristics

This paper is based on a novel shape of asymmetric few-leaf spring, which is used in the traditional parabolic leaf spring. By means of experiments and finite element method,we compared the stressdistribution and kinemat...

Review Of Experimental And Numerical Analysis Of Heat Exchanger In The Light Of Waste Heat Recovery Applications

The present work has been carried out with a review of the performance of a helical coil heat exchanger in the light of waste heat recovery applications. In maximum cases analysis was done for number of cases and the eff...

Gravity Lamp

In recent times due to effects of pollution and global warming there is a need for generating power from renewable sources. The reason for generating power using gravity is that it is available all over the Earth, abunda...

Download PDF file
  • EP ID EP391011
  • DOI 10.9790/9622-0704052427.
  • Views 140
  • Downloads 0

How To Cite

Vikky Kumhar, Amit Sarda (2017). Design and Analysis of Total Elbow Replacement Joint. International Journal of engineering Research and Applications, 7(4), 24-27. https://europub.co.uk/articles/-A-391011