Design and Implementation of Photo-induced Heart Beat Monitoring System

Journal Title: Journal of Advances in Mathematics and Computer Science - Year 2017, Vol 20, Issue 4

Abstract

This study presents the design of photo-induced heart beat monitor that uses cheap and readily available materials unlike most of all the rather sophisticated heart beat monitoring devices that uses complicated designs and therefore needs the help of an expert to carry out the exercise and also to do the interpretation for users, this device is simple, portable, affordable and easy to operate. This is based on principle and technique of measuring the heart beat with the method of photo induction, through a fingertip using a PIC16F877A Microcontroller interface to a Digital Display for data logging and further analysis of signals generated as a result of such activities. The circuit designed is made up of different stages which involve sensing the Finger Tip through Infrared Receiver; Filtering the Signal, thereby measuring the Heartbeat with the PIC16F877A Microcontroller; calculating through the connected Local Clock Signal and displaying the Result through the 2 X 16 Liquid Crystal Display (LCD) Output. It is therefore a useful design for everyone that wishes to stay healthy and monitor their heart rate for early detection of hypertension and heart related ailments. This design is highly versatile and economical. It can be used everywhere at anytime. It is safe, convenient and easy to use.

Authors and Affiliations

Olokun Mayowa Samuel

Keywords

Related Articles

DT- optimality Criteria for Second Order Rotatable Designs Constructed Using Balanced Incomplete Block Design

Experimenters have come to a realization that a design can perform very well in terms of a particular statistical characteristic and still perform poorly in terms of a rival characteristic. Due to this studies have narro...

On Properties Related To *–Reversible Rings

In this paper, a class of *-rings which is a generalization of *–reversible rings is introduced. A ring with involution * is called central *–reversible if for a ,b∈R, whenever ab=0 ,b^* a is central in R. Since every *–...

Viscosity Approximation Methods in Reflexive Banach Spaces with a Sequence of Contractions

The aim of this paper is to study viscosity approximation methods in re exive Banach spaces. Let E be a re exive Banach space which admits a weakly sequentially continuous duality mapping j : E → E  , C a nonempty close...

On Generalized Douglas - Kropina Spaces

Sakaguchi proved that the class of Weyl metrics belong to the class of generalized Douglas{Weyl metric. Then, Matsumoto studied Weyl{Kropina metric. Recently, Yoshikawa and Okubo obtained the conditions for a Kropina spa...

Cyclic-union Operation to Obtain Latin Squares

With the power that has taken the information technologies, one has developed the study and research about cryptography, and cryptanalysis, in which Latin squares are ideal candidates for being used in cryptographic syst...

Download PDF file
  • EP ID EP322463
  • DOI 10.9734/BJMCS/2017/28023
  • Views 83
  • Downloads 0

How To Cite

Olokun Mayowa Samuel (2017). Design and Implementation of Photo-induced Heart Beat Monitoring System. Journal of Advances in Mathematics and Computer Science, 20(4), 1-14. https://europub.co.uk/articles/-A-322463