Design and Performance Evaluation of Solar Liquid Desiccant System

Journal Title: GRD Journal for Engineering - Year 2017, Vol 2, Issue 6

Abstract

Human comfortness is essential now a day because of the improvement in life style and increasing atmospheric temperature. Electrical air conditioning machines are not most suitable for large buildings because of the higher power consumption and shorter life. Central air conditioning or chilled water system is more reliable for easy operation with a lower maintenance cost for large building. With large buildings such as commercial complex, auditorium, office buildings are provided with central air conditioning system. Educational and research institutions, Hotels, Hospitals, malls etc. are also need human comfortness, as the population of student community increase year by year. The effective design of central air conditioning or a chiller system can provide lower power consumption, capital cost and improve aesthetics of a building. This paper establishes the results of cooling load calculation of different climate conditions by installing dehumidifier. By using CLTD method and Carrier program then the results are compared for a single-story building which is a part of an institute. Cooling load items such as, Electrical equipments, people heat gain, lighting heat gain, infiltration and ventilation heat gain can easily be putted to the MS-Excel programme. The programme can also be used to calculate cooling load due to walls and roofs. And results were compared with the standard data given by ASHRAE and CARRIER Fundamental Hand Books, hourly analysis programme and results are satisfactory. It is also seen that in this paper cooling requirement of without dehumidifier is about 20 % more as compare to with dehumidifier for climate condition of Thiruvanathapuram, Kerala in India. It will be a significant for a large commercial building.

Authors and Affiliations

Prof. Jacob Kuriyakose, Libin RS, Prof. Sunil Mathew Roy, Adarsh Kumar

Keywords

Related Articles

Design and Analysis of Electromagnetic Disc Brake for Automobiles

The design of an electromagnetic disc brake requires a multidisciplinary approach. Its performance is an outcome of usage of concepts from various fields viz. mechanical, electrical, magnetic and material engineering. Th...

Performance Evaluation Study of an Innovative Material to Improve The Strength of Conventional Concrete

Concrete is an absolute essential material use for construction. Despite of its versatility in construction. It is known to have several limitations. It is having limited ductility and less resistance to cracking, so con...

Passive Viscoelastic Constrained Layer Damping for Beams

Beam is basic components in industrial structural design whose damping properties are often very important to reduce vibration. Viscoelastic materials are generally polymers; there is enormous variability in the composit...

Design and Fabrication of Automatic Railway Track Crack Detection System

The Indian railway has one of the largest railway networks in the World, over 1, 15,000 km in distance. A recent study revealed a Fact that over 25% of the track length is in need of replacement Due to development of cra...

Rich Internet Application for Weekly Automatic College Time Table Generation

The manual system of preparing time table in colleges with large number of students is very time consuming and usually ends up with various classes clashing either at same room or with same teachers having more than one...

Download PDF file
  • EP ID EP224912
  • DOI -
  • Views 81
  • Downloads 0

How To Cite

Prof. Jacob Kuriyakose, Libin RS, Prof. Sunil Mathew Roy, Adarsh Kumar (2017). Design and Performance Evaluation of Solar Liquid Desiccant System. GRD Journal for Engineering, 2(6), 261-266. https://europub.co.uk/articles/-A-224912