Detection of Differently Loaded Power Network Areas

Journal Title: Acta Energetica - Year 2016, Vol 27, Issue 2

Abstract

A widely accepted method of simplifying power system problems, especially for large system, is solving them for areas into which a system is divided. The paper considers separation of the power system areas that contain branches with similar active or reactive power loads. For this purpose rates are proposed that show the dependence of the branch power flow (active and reactive power flow separately) on the loads at system nodes. On the basis of the considered rates, branches are partioned into groups. The rates for all branches in the same group are similar. They significantly differ between groups. For selected groups of branches, which are characterized by values of the aforementioned rate larger than a preset value, the consistent area of the power network is found. The paper shows utilization of the method for the IEEE 14-bus test system.

Authors and Affiliations

Tomasz Okoń, Kazimierz Wilkosz

Keywords

Related Articles

Performance Analysis of Power Boiler Drum Water Level Control Systems

Described in the paper are the structures of water level controls in power boiler drums. A boiler drum’s function is very important for the power unit process, because this is where water separates from steam, which is t...

Proposed Amendments to Reactive Energy Billing

This paper describes possible amendments to the rules of reactive energy billing in the tariffs in Poland. Modifications in the tariffs to improve their motivational function for distribution system users are identified...

Types of Risks in the Process of Investing in Renewable Electric Energy Sources

The development of renewable power engineering is inevitable. Administrative, financial, political, social, environmental or technical/technological barriers are and must be minimized. They determine the scale of risk bo...

Balancing the Unbalanced Supply of Generation Sources – Additional Costs in a Competitive Energy Market

Trade balancing of balancing mechanism units entails additional costs of electricity purchases for consumers’ own needs. Trading companies constantly look for effective tools to reduce the costs of their operations in th...

Design of Transformers

In this paper the basic designing of high voltage power transformers has been described. The layout and construction of a high voltage and low voltage winding of transformers has been determined. The designing of a tank...

Download PDF file
  • EP ID EP199638
  • DOI 10.12736/issn.2300-3022.2016215
  • Views 72
  • Downloads 0

How To Cite

Tomasz Okoń, Kazimierz Wilkosz (2016). Detection of Differently Loaded Power Network Areas. Acta Energetica, 27(2), 166-170. https://europub.co.uk/articles/-A-199638