Abstract

A widely accepted method of simplifying power system problems, especially for large system, is solving them for areas into which a system is divided. The paper considers separation of the power system areas that contain branches with similar active or reactive power loads. For this purpose rates are proposed that show the dependence of the branch power flow (active and reactive power flow separately) on the loads at system nodes. On the basis of the considered rates, branches are partioned into groups. The rates for all branches in the same group are similar. They significantly differ between groups. For selected groups of branches, which are characterized by values of the aforementioned rate larger than a preset value, the consistent area of the power network is found. The paper shows utilization of the method for the IEEE 14-bus test system.

Authors and Affiliations

Tomasz Okoń, Kazimierz Wilkosz

Keywords

Related Articles

Electricity Distribution Effectiveness

This paper discusses the basic concepts of cost accounting in the power industry and selected ways of assessing the effectiveness of electricity distribution. The results of effectiveness analysis of MV/LV distribution t...

Performance Analysis of Power Boiler Drum Water Level Control Systems

Described in the paper are the structures of water level controls in power boiler drums. A boiler drum’s function is very important for the power unit process, because this is where water separates from steam, which is t...

Pseudo-random Simulation of Synchronous Interconnections of Polish and German 110 kV Grids

The is a study of the power supply of a separated portion of a 110 kV grid on the Polish side from the German 110 kV grid. The Polish and German power systems are interconnected by exchange lines on the level of 400 kV a...

Problems of Connecting Wind Farms to the Power System with HV Cables

This paper presents problems caused by connecting wind farms to a power system with high voltage cables. The author highlights possible problems with reactive power compensation, depending on the arrangement of the shunt...

Proposed Amendments to Reactive Energy Billing

This paper describes possible amendments to the rules of reactive energy billing in the tariffs in Poland. Modifications in the tariffs to improve their motivational function for distribution system users are identified...

Download PDF file
  • EP ID EP199638
  • DOI 10.12736/issn.2300-3022.2016215
  • Views 57
  • Downloads 0

How To Cite

Tomasz Okoń, Kazimierz Wilkosz (2016). Detection of Differently Loaded Power Network Areas. Acta Energetica, 27(2), 166-170. https://europub.co.uk/articles/-A-199638