Detection of Kidney Abnormalities in Noisy Ultrasound Image

Abstract

Ultrasound imaging is a widely used and safe medical diagnostic technique, due to its non-invasive nature, low cost and capability of forming real time imaging. Ultrasound imaging uses high-frequency sound to image internal structures by differing reflection signals produced when a beam of sound is projected into the body and bounces back at interfaces between the structures. However the usefulness of ultrasound imaging is degraded by the presence of signal dependant noise known as speckle. The speckle pattern depends on the structure of the image tissue and various imaging parameters. Speckle noise present in ultrasound image affects edges and fine details which limit the contrast resolution and make diagnostic more difficult. There are two main purposes for speckle reduction in medical ultrasound imaging (1) to improve the human interpretation of ultrasound images (2) despeckling is the preprocessing step for many ultrasound image processing tasks such as segmentation and registration. A number of methods have been proposed for speckle reduction in ultrasound imaging.

Authors and Affiliations

Shruthi B, S Renukalatha Last Name, M Siddappa

Keywords

Related Articles

Enhancement of COP by using Liquid Line-Suction Line Heat Exchanger at Various Lengths with Refrigerant R-134a

Improvement of performance of system is very much important for higher refrigerating effect or reduced power consumption for same refrigerating effect. By sub-cooling using heat exchanger at condenser inlet refrigeratin...

Active Power Loss Minimization Using Simultaneous Network Reconfiguration and DG Placement with AGPSO Algorithm

This paper presents a new approach has been proposed to solve network reconfiguration in the presence of distributed generation (DG) in distribution system with an objective of minimization real power loss and improving...

Experimental Investigation of Heat Transfer Enhancement Using U-Cut Semicircular Ring Turbulators in Double Pipe Heat Exchanger

Heat enhancement techniques are being utilized for many decades by evaluating different parameters of heat exchangers. Various types of configuration of heat exchanger are analyzed so far with various types of mechanica...

Designing Parameters and Study of 8 KW Solar PV Grid Connected System (A Case Study)

The purpose of this paper is to provide the real information about 8KW Solar Photo Voltaic System. The conventional energy sources like coal, petroleum and fossil fuels are limited in nature. About 55% of energy is prod...

Seed Deterioration in Eruca sativa (Miller) Thell. Varieties: Comparative factors between Seeds and Leaves

The present study focuses on the role of oxidative stress and the antioxidant defense mechanism in deteriorated seed of Eruca sativa (Miller) Thell. Fifteen varieties were undertaken to demonstrate the effect of seed de...

Download PDF file
  • EP ID EP20951
  • DOI -
  • Views 233
  • Downloads 5

How To Cite

Shruthi B, S Renukalatha Last Name, M Siddappa (2015). Detection of Kidney Abnormalities in Noisy Ultrasound Image. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 3(6), -. https://europub.co.uk/articles/-A-20951