DETERMINATION OF PULSATION FACTORS OF THE SYSTEM OF SUPPRESSION OF INTERFERING HARMONICS OF A SEMICONDUCTOR CONVERTER
Journal Title: Електротехніка і Електромеханіка - Year 2018, Vol 0, Issue 4
Abstract
Purpose. The purpose of the paper is to define the pulsation factors of a closed-loop automatic control system (ACS) of interfering harmonics containing a semiconductor converter with double-sided pulse-width modulation (PWM), as well as confirmation of theoretical assumptions about possibilities of self-compensation of pulsation factors’ influence in the system with double-sided PWM. Methodology. The research was conducted with the usage of classic electric circuit theory, frequency analysis methods, generalized function theory. Results. The obtained expressions mathematically relate pulsation factors, value of the damping coefficient and manipulative variable for different frequencies of interfering harmonics in the system with double-sided PWM. The research concerned harmonics with frequencies 100, 300, 600, 900 and 1200 Hz as the most significant constituents of the output voltage of a 12-pulse semiconductor converter. The obtained expressions allow taking into account settings of the selective link and its approximation on the level of supreme frequencies with aperiodic link. Originality. The research has experimentally proved theoretical assumptions about self-compensation of pulsation factors in the system with double-sided PWM. It has been shown that the damping coefficient has a low-impact influence on the values of pulsation factors. It is caused by the pass band of the selective link, which is included in the closed-loop control system of harmonics regulation. Practical value. Application of the research results can contribute to the development of the closed-loop control system for effective attenuation of interfering harmonics in direct current contact wire without interfering in the power part of the semiconductor converter. Besides the possibility to regulate output voltage, it will also help to solve the problem of electromagnetic compatibility of a traction substation semiconductor converter with contact wire. The application of the developed closed-loop control system will as well provide for decreasing the size of the filter in the direct current traction substation unit.
Authors and Affiliations
V. V. Panchenko, A. S. Maslii, D. P. Pomazan, S. G. Buriakovskyi
REACTIVE CURRENT OF AN INDUCTION ELECTRIC DRIVES WITH THYRISTOR VOLTAGE REGULATOR
A model for a separation of reactive constituent from current of idling of an induction motor at its feed from a thyristor voltage regulator in the dependences on the control angle of thyristors is developed. As a result...
MAGNETIC-PULSE CAR BODY PANELS FLATTENING. THEORETICAL ASPECTS AND PRACTICAL RESULTS
The aim of the article is to provide theoretical and experimental studying of the «induction system with an attractive screen» prac-tical effectiveness with the excited magnetic pulse attractive forces numerical estimati...
IMPROVED ALGORITHM FOR CALCULATING COMPLEX NON-EQUIPOTENTIAL GROUNDING DEVICES OF ELECTRICAL INSTALLATIONS TAKING INTO ACCOUNT CONDUCTIVITY OF NATURAL GROUNDINGS
Purpose. The method of natural concentrated groundings substitution by the set of electrodes taking them into account in the algorithm of electric characteristics calculation for complicated grounding connections of elec...
AN IMPROVED CONTROL ALGORITHM FOR «DYNAMIC CAPACITOR» VAR COMPENSATOR
Purpose. Modern approaches of VAR compensation are: using compensators with stepped regulation, STATCOMs, active pow-er filters. Recently, more attention is paid to VAR compensator’s design based on the direct AC / AC co...
MODELING OF AN ADVANCED HEAT EXCHANGE UNIT WITH MICROCHANNELS FOR A COMBINED PHOTOENERGY SYSTEM
Purpose. Mathematical modeling of the heat exchange unit main parameters for photoenergy system based on general models with forced circulation of heat transfer fluid. Methodology. To determine the coefficient of heat tr...