DETERMINATION OF PULSATION FACTORS OF THE SYSTEM OF SUPPRESSION OF INTERFERING HARMONICS OF A SEMICONDUCTOR CONVERTER

Abstract

Purpose. The purpose of the paper is to define the pulsation factors of a closed-loop automatic control system (ACS) of interfering harmonics containing a semiconductor converter with double-sided pulse-width modulation (PWM), as well as confirmation of theoretical assumptions about possibilities of self-compensation of pulsation factors’ influence in the system with double-sided PWM. Methodology. The research was conducted with the usage of classic electric circuit theory, frequency analysis methods, generalized function theory. Results. The obtained expressions mathematically relate pulsation factors, value of the damping coefficient and manipulative variable for different frequencies of interfering harmonics in the system with double-sided PWM. The research concerned harmonics with frequencies 100, 300, 600, 900 and 1200 Hz as the most significant constituents of the output voltage of a 12-pulse semiconductor converter. The obtained expressions allow taking into account settings of the selective link and its approximation on the level of supreme frequencies with aperiodic link. Originality. The research has experimentally proved theoretical assumptions about self-compensation of pulsation factors in the system with double-sided PWM. It has been shown that the damping coefficient has a low-impact influence on the values of pulsation factors. It is caused by the pass band of the selective link, which is included in the closed-loop control system of harmonics regulation. Practical value. Application of the research results can contribute to the development of the closed-loop control system for effective attenuation of interfering harmonics in direct current contact wire without interfering in the power part of the semiconductor converter. Besides the possibility to regulate output voltage, it will also help to solve the problem of electromagnetic compatibility of a traction substation semiconductor converter with contact wire. The application of the developed closed-loop control system will as well provide for decreasing the size of the filter in the direct current traction substation unit.

Authors and Affiliations

V. V. Panchenko, A. S. Maslii, D. P. Pomazan, S. G. Buriakovskyi

Keywords

Related Articles

TECHNICAL AND ECONOMIC ASPECTS OF ELECTRIC MACHINE INDUSTRY DEVELOPMENT WITH ACCOUNT OF ELECTRIC POWER DEVELOPMENT DIRECTIONS

A critical assessment of the existing views on the world energy development prospects is an integral part of independent policy elaboration in this field for any state. Consideration of prospective power industry develop...

MODELING CONTROLLED ASYNCHRONOUS ELECTRIC DRIVES WITH MATCHING REDUCERS AND TRANSFORMERS

Purpose. Working out of mathematical models of the speed-controlled induction electric drives ensuring joint consideration of transformers, motors and loadings, and also matching reducers and transformers, both in static...

THE DIAGNOSTICS OF INDUCTION MOTORS ROTOR BAR BREAKS BASED ON THE ANALYSIS OF ELECTROMOTIVE FORCE IN THE STATOR WINDINGS

A method for diagnostics of the induction motor rotor bar breaks, based on the wavelet-analysis of the electromotive force induced in the stator windings in the rundown mode is developed. A method for decomposition of th...

NUMERICAL ANALYSIS OF MATHEMATICAL MODELS OF THE FACTUAL CONTRIBUTION DISTRIBUTION IN ASYMMETRY AND DEVIATION OF VOLTAGE AT THE COMMON COUPLING POINTS OF ENERGY SUPPLY SYSTEMS

Purpose. Perform numerical analysis of the distribution of the factual contributions of line sources of distortion in the voltage distortion at the point of common coupling, based on the principles of superposition and e...

MAGNETIC FIELD IN A GAP OF ELECTROMECHANICAL DISINTEGRATORS

The magnetic field created in an air gap of electromechanical disintegrators as a result of actions of two opposite running magnetic fields is considered. It is shown that motionless pulsing fields are as a result formed...

Download PDF file
  • EP ID EP491112
  • DOI 10.20998/2074-272X.2018.4.04
  • Views 69
  • Downloads 0

How To Cite

V. V. Panchenko, A. S. Maslii, D. P. Pomazan, S. G. Buriakovskyi (2018). DETERMINATION OF PULSATION FACTORS OF THE SYSTEM OF SUPPRESSION OF INTERFERING HARMONICS OF A SEMICONDUCTOR CONVERTER. Електротехніка і Електромеханіка, 0(4), 24-28. https://europub.co.uk/articles/-A-491112