Development and validation of inductively coupled plasma mass spectrometry method for simultaneous determination of tin (SN) levels in excipients and formulations

Abstract

The pharmaceutical dosage form manufacturing process use some of polymers, which contains traces of inorganic elements like Tin (Sn) content. The traces of inorganic elements were determined by using inductively coupled plasma mass spectroscopy (ICP-MS). It is a sensitive method used to determine the inorganic elements by atomic mass value. In the present study Tin (Sn) was extracted by the sample using microwave-assisted digestion with hydrochloric acid. Different validation parameters were employed to evaluate the method in terms of selectivity, specificity, method precision, accuracy, intermediate precision and standard measurement uncertainty. The mass value of tin element is 118 as per the Perkin Elmer instrument recommendations. The results indicate that this method could be used for the routine measurement of tin (Sn) in the pharmaceutical laboratories.

Authors and Affiliations

Jagadeswara Rao K, Murali Mohan SV, Rama Rao Malla

Keywords

Related Articles

Formulation and evaluation of lornoxicam emulgel

Transdermal route of administration of drug is effective route of administration for different kind of indications. The purpose of present investigation was to develop Lornoxicam emulgel for systemic effect and to avoid...

Burn wound healing potentials of Cynodon dactylon (L.) Pers.

In this study the hydroalcoholic extract of the plant Cynodon dactylon L Pers was undertaken to evaluate the wound healing property on Burn Wound Model and to compare the effect of the combination of hydroalcoholic extra...

Formulation and evaluation of sustained release mucoadhesive microspheres of lornoxicam by using novel isolated polymer of fruit artocarpus heterophyllus

Objective To investigate the potential of novel polymer isolated from fruit Artocarpus heterophyllus for mucoadhesion and sustained release action Microspheres containing Lornoxicam formulated using isolated polymer offe...

Brief update on management of hypertension in diabetic patients

Nowadays there is increased prevalence of co-morbidity of hypertension and diabetes. Hypertension has become such a bigger health problem as it does not show any manifestation of it until it gets seriously complicated. H...

Comparative study of olanzapine and risperidone in the control of positive and negative symptoms in the treatment of schizophrenia

Objective To compare the efficacy of olanzapine and risperidone in the treatment of positive and negative symptoms of schizophreniaMaterials and Methods The study was conducted in MGM medical college Navi Mumbai between...

Download PDF file
  • EP ID EP310594
  • DOI 10.18231/2394-2797.2017.0017
  • Views 87
  • Downloads 0

How To Cite

Jagadeswara Rao K, Murali Mohan SV, Rama Rao Malla (2017). Development and validation of inductively coupled plasma mass spectrometry method for simultaneous determination of tin (SN) levels in excipients and formulations. International Journal of Pharmaceutical Chemistry and Analysis, 4(3), 70-78. https://europub.co.uk/articles/-A-310594