Diagnostic of power transformers are in service long time

Abstract

Purpose. Improvement of power transformer condition diagnostic being in service long time. Methodology. The theoretical aspects of the paper are based on theory fundamental statements of electrical apparatus and material engineering. Experimental investigations were real-ized by monitoring data incisive analysis of capacitor (С) and approximate power factor (tgδ) of autotransformer bushing 550 kV on operating equipment. Results. Results and observational analysis are given. They show that power transformer diagnostic recommended methods in operation do not be able to in full detect defects with accumulative character appearing during a continuous exploitation peri-od. Originality. In addition to the existing methods of power transformers diagnostic to use a technique based on the registration of par-tial discharges is proposed. It allows detecting insulation defects at early stages of development. Due to the fact that current value of parti-cle discharges is not large especially in the initial stages, it make sense for studding of partial discharges in transformer insulation to fix electrical field and acoustic signals generating partial discharges. Practical value. Practical value for electrotechnical branch is improve-ment diagnostic and enhancement of safety of substation equipments exploitation.

Authors and Affiliations

O. G. Volkova, L. B. Zhorniak, I. V. Lyevyenkov

Keywords

Related Articles

The choice of a rational number of sources of power system load mutual traction electrical machines

Problems of selection of rational variants of traction electric machines mutual loading schemes to carry out their acceptance test are considered. It is substantiated that discrepancy of magnetic characteristics of tract...

Regulation regime functioning electric circuit illuminating plant (sistems)

It was analysing the possibility of pulse-fase and operating regime of lighting options to optimace lighting fnd electrotechnical parameter-sand to increase the reliable fnd powerefficienty.The theristor options, what wa...

Development latch short-circuit for overhead power line voltage of 110 - 150 kV

Proposed a simple design of electromechanical latch short-circuit for overhead power line voltage of 110-150 kV. For the selected constructions shows a method of calculating its technical characteristics. Experimentally...

Analysis of electromagnetic processes in a converter with a decondon voltage regulation and electromechanical load

The new mathematical models of the electromagnetic processes is designed in threephase electric circuit of the semiconductor converters with many-server zoned regulation phases voltages disregarding losses in semiconduct...

A technique for induction cookers’ inductors calculation

In the paper a technique for the calculation of inductor – main structural part of an induction cooker is proposed. The presented technique is developed on the base of engineering methods for calculation of industrial in...

Download PDF file
  • EP ID EP435013
  • DOI 10.20998/2079-3944.2018.32.01
  • Views 123
  • Downloads 0

How To Cite

O. G. Volkova, L. B. Zhorniak, I. V. Lyevyenkov (2018). Diagnostic of power transformers are in service long time. Вісник Національного технічного університету "ХПІ". Серія: Проблеми удосконалювання електричних машин і апаратів. Теорія і практика, 32(1308), 3-7. https://europub.co.uk/articles/-A-435013