Different Role of Left Atrial Size and Function in Patients with Paroxysmal versus Persistent Atrial Fibrillation. Wellnhofer: LA Size & Function in Atrial Fibrillation
Journal Title: Journal of Cardiobiology - Year 2013, Vol 1, Issue 1
Abstract
Purpose: Pulmonary vein isolation (PVI) is established as interventional treatment in atrial fibrillation (AF). Recent studies suggest that atrial reservoir function (preload) is involved in initiation of paroxysmal AF (AFparox) and conduit function (after-load) may be crucial in persistent AF (AFpers). Methods: We enrolled 336 consecutive patients scheduled for PVI (age 60±10 years). Point-to-point radiofrequency ablation was used in the majority of cases. Success was defined as a minimum of 3 months (median 12 months) follow-up as absence of recurrence of AF in any Holter ECG since PVI. Results: Patients with recurrent AFparox demonstrated a significantly better outcome (64% success) than patients with AFpers (41% success). AFparox patients were 5 years younger and had smaller atria, a better emptying index, higher systolic pulmonary venous velocity, and only borderline impaired diastolic left ventricular function. LA size per se was not related to success in AFparox. Left ventricular filling times (Tfill) and the ratio of systolic to diastolic tissue Doppler (TDI) velocity (S’/E’) were found to be potential risk predictors. Increased LA-size, reduced LA-emptying and impaired diastolic left ventricular function were found in AFpers patients. S’/E’ and isovolumic relaxation time stratify risk in AFpers patients. Conclusions: In AFparox long term failure of primary PVI is associated with restrictive reservoir function but not LA enlargement. Whereas in AFpers a combination of severely reduced LA emptying, increased LA size and severely impaired diastolic LV function result in a high rate of recurrent AF. TDI (Tfill, S’/E’) may help to improve risk stratification.
Authors and Affiliations
Ernst Wellnhofer
Validation of a Device for High Fidelity Correction of Pressure Signals from Fluid-Filled Systems by Harmonic Analysis
Fluid-filled systems are generally used for invasive pressure measurements in cardiology, anesthesiology and intensive care medicine. Wave reflection and attenuation cause considerable signal distortion. The article pres...
Treatment of Tricuspid Regurgitation Following Heart Transplantation: Surgical Approach and Result
Background: Tricuspid valve regurgitation is common after heart transplantation, but the need for replacement or repair is rare. Patients with signs of advanced right-sided heart failure are considered at higher risk for...
Matrix Metalloproteinases -14, -9 and -2 are Localized to the Podosome and Involved in Podosome Development in the A7r5 Smooth Muscle Cell
Aim: The purpose of the study was to localize matrix metalloproteinase (MMP)-14, -9, and -2 in the A7r5 smooth musclecell nd to understand the interaction between these MMPs and the cytoskeleton. This interaction was o...
Lithium Toxicity and Level Dependent Sinoatrial Exit Block
Background: Lithium toxicity has been associated with variable changes on Electrocardiogram (ECG) but several long pauses secondary to Sinoatrial (SA) exit block have not been formally reported. Conclusion: Our case h...
New Onset of Left Ventricular Dysfunction Associated with Selenium, Zinc and Copper Deficiency Presenting Late after Gastric Bypass Surgery: Case Report and Review of the Literature
The increasing rate of obesity and heart disease remain a global epidemic. Since 1980, the obesity rate has more than doubled to 1.4 billion adults worldwide and is related to 23% of all cases of ischemic heart disease [...