Does Improved Technology in SPECT Myocardial Perfusion Imaging Reduce Downstream Costs? An Observational Study
Journal Title: International Journal of Radiology and Imaging Technology - Year 2017, Vol 3, Issue 1
Abstract
Background: Advances in myocardial perfusion imaging (MPI), including CT attenuation correction (CTAC) and advanced image reconstruction algorithms, result in improved image quality, thus reducing equivocal or false positive results. This theoretically decreases the need for downstream testing; however, there is limited access to these technologies due to their costs and the magnitude of benefit remains unclear. We performed an observational study to evaluate the effect of implementing a SPECT/CT system with advanced image reconstruction algorithms on diagnostic accuracy of MPI, and its effect on downstream healthcare expenditures. Methods: 277 consecutive patients who underwent SPECT MPI with a traditional SPECT camera were compared to 273 patients imaged at the same institution with a new SPECT/CT system with advanced image reconstruction algorithms. Accuracy of MPI was assessed in a subgroup of 36 and 26 consecutive patients in the traditional SPECT and SPECT/CT groups respectively, who underwent clinically-indicated invasive coronary angiography (ICA). Utilization of medical services related to coronary artery disease (CAD) was tabulated for the year following SPECT MPI and mean cost of services was estimated using national Medicare reimbursement data. Results: MPI studies performed on the SPECT/CT system were more likely to be overall true positive (62% vs. 25%; p = 0.008) and less likely to be false positive (19% vs. 56%; p = 0.004). Fewer false positive MPI studies resulted in fewer patients undergoing diagnostic ICA procedures (4% vs. 9%; p = 0.03). Among patients with additional CAD-related services within one year, total downstream healthcare cost was not significantly decreased, but mean expenditure on diagnostic healthcare services was lower in the SPECT/CT group ($4288 vs. $5740; p = 0.04). Conclusions: Use of SPECT/CT with advanced image reconstruction software for MPI can result in more efficient downstream utilization of diagnostic ICA and reduced downstream diagnostic expenditures.
Establishing Radiopharmaceutical Standards at a Nuclear Medicine Unit in Malta
Purpose:To establish radiopharmaceutical standards in a Nuclear Medicine Department in terms of radiochemical purity. Radionuclide standards were assessed in terms of radionuclide and chemical purity as well as pH as par...
Radiation-Induced Maxillary Osteosarcoma and Synchronous Oropharyngeal Squamous Cell Cancer: A Rare Case Report
Radiotherapy is a treatment option for nasopharyngeal cancer. However, ionizing radiation may lead to development of secondary malignancies. In this case report, we will present a case of radiation-induced osteosarcoma o...
Axillary Castleman's Disease: A Rare Case Report
Castleman's Disease (CD) is a rare benign lymphoproliferative disorder of uncertain origin which most commonly involves the mediastinum but rarely affects the axilla. We report a case of voluminous axillary unicentral CD...
Alternative Mathematical Form for Determining the Effectiveness of High-LET Radiations at Lower Doses Region
The Effectiveness of lower doses of high-LET radiations is not accurately determined by using energy-based physical parameters such as absorbed dose and radio-sensitivity parameters. Therefore, an attempt has been carrie...
Aberrant Internal Carotid Artery in the Temporal Bone: A Case Report
An aberrant internal carotid artery (ICA) in the middle ear is a rare and potentially serious vascular anomaly. Symptoms and signs of aberrant internal carotid artery are often non-specific, therefore radiographic invest...