Does Normalised Apparent Diffusion Coefficient Further Improve the Diagnostic Accuracy of Diffusion-Weighted MRI at 3T in Characterising Breast Masses?

Journal Title: Journal of Clinical and Diagnostic Research - Year 2019, Vol 13, Issue 4

Abstract

ABSTRACT Introduction: In recent times, a significant rise has been observed in the incidence of breast cancer among Indian women. Breast Magnetic Resonance Imaging (MRI) plays an adjuvant role in the high risk screening, diagnosis, staging and follow-up of breast cancer. It is used as a complementary tool to mammography and ultrasound for the diagnostic work-up of breast masses. An advanced MRI technique such as Diffusion-Weighted Imaging (DWI) with quantitative absolute and normalised Apparent Diffusion Coefficient (ADC) measurements is employed to improve the diagnostic performance of Contrast-Enhanced Breast MRI (CE-MRI). Aim: To assess whether glandular tissue-normalised Apparent Diffusion Coefficient (nADC) could further improve the diagnostic accuracy of MRI, in characterising benign versus malignant breast masses. Materials and Methods: This cross-sectional study included 39 patients with 51 focal breast masses. These patients underwent CE-MRI and DWI, on a 3T MR system. Absolute ADC values and glandular tissue-normalised ADC values were measured in the breast masses satisfying the inclusion criteria. The diagnostic accuracy and kappa measure of agreement between the diagnoses obtained from various imaging techniques (independently and in combination) and the final histopathology/follow-up results were calculated. Results: Twenty six (51%) of the 51 breast masses were benign and 25 (49%) were malignant. The mean nADC value (0.619+0.21×10−3 mm2/sec) obtained from malignant breast masses was significantly lower than the mean nADC value (0.98+0.26×10−3 mm2/sec) measured from benign breast masses (p<0.05). Adding, normalised ADC to CE-MRI, increased the specificity of breast MRI in differentiating benign from malignant breast masses, from 88.5% to 92.3% and improved its kappa score of agreement with histopathology or follow-up results, from 0.883 to 0.960. Receiver Operating Characteristic (ROC) curve analysis indicated that the Area Under Curve (AUC) for nADC (0.870) was higher than the AUC for absolute ADC (0.809). Conclusion: Quantitative DWI with glandular tissue-normalised ADC mapping at 3T, improves the diagnostic performance of breast MRI in characterising breast masses; especially in a subset of masses with borderline CE-MRI findings and absolute ADC values.

Authors and Affiliations

Varsha S Hardas, Aparna H Chandorkar, Aparna A Atre

Keywords

Related Articles

Obstructive Uropathy with Renal Failure

ABSTRACT Introduction: Renal failure is often seen with Urinary Tract Obstruction (UTO), which could be acute or chronic (obstructive nephropathy). With early diagnosis and treatment, it is often reversible. The data bei...

Plasma Neutrophil Elastase and its Endogenous Inhibitors as Differential Inflammatory Markers for Dengue and Pneumonia

ABSTRACT Introduction: Neutrophils play a crucial role in protecting the host against microbial pathogens but they produce proteolytic enzymes such as Neutrophil Elastase (NE), the uncontrolled activity of which can dest...

Benefits of Alcohol on Arsenic Toxicity in Rats

Introduction: It has been demonstrated earlier that exposure to ethanol and/or arsenic compounds (such as sodium arsenite) produces toxic effects as shown by both in vitro and in vivo experiments. Chronic exposure of hum...

Sciatic Nerve Schwannoma at Sciatic Foramen: Importance of Transvaginal Sonography Guided Biopsy and Magnetic Resonance Imaging in its Diagnosis

ABSTRACT Schwannomas are truly encapsulated benign tumours associated with the nerves arising from the schwann cells. Schwannomas arising from the sciatic nerve is of rare occurrence and is estimated to be less than one...

Factors Affecting Medication Errors from the Perspective of Nursing Staff

ABSTRACT Introduction: Medication administration is a key responsibility of nurses. If this duty is not properly accomplished, it can cause serious threats to the health and safety of patients. Aim: To explore factors af...

Download PDF file
  • EP ID EP554796
  • DOI 10.7860/JCDR/2019/40523.12800
  • Views 62
  • Downloads 0

How To Cite

Varsha S Hardas, Aparna H Chandorkar, Aparna A Atre (2019). Does Normalised Apparent Diffusion Coefficient Further Improve the Diagnostic Accuracy of Diffusion-Weighted MRI at 3T in Characterising Breast Masses?. Journal of Clinical and Diagnostic Research, 13(4), 1-6. https://europub.co.uk/articles/-A-554796