Dose Calibration and Track Diameter Distribution for 241Am-Be Neutron Source, Using CR-39 Nuclear Track Methodology.

Abstract

In neutron detection, the more common method is using electronic instrumentation associate with Bonner spheres, however, currently the Nuclear Tracks Methodology (NTM) is coming popular because of the simplicity, flexibility in size of the detector, no requirement for sophisticated instrumentation and installation, and low cost. In this work, a preliminary result of the dose calibration and track diameter distribution of Americium-Beryllium (241Am-Be) source using Nuclear Track Methodology is presented. As material detector, CR-39 polycarbonate, cut in 1.8 × 0.9 cm2 chips was chosen, and two step chemical etchings after neutron exposure was used to develop the tracks. The irradiations were made in environmental normal conditions, in the ORNL neutron calibration facilities. The CR-39 chips were placed in a phantom, with 3mm plastic (Lexan) sheet in between the source and detectors to increase the proton generation. The total track density and track diameter distribution was performing in a Counting and Analysis Digital Image System (CADIS), developed at the Institute of Physics of the University of Mexico UNAM. The results are compared with a standard survey instrument and energy reference spectra of the International Atomic Energy Agency (IAEA).

Authors and Affiliations

J. S. Bogard, J. I. Golzarri, G. Espinosa

Keywords

Related Articles

The Three-Body Structure of 2n and 2p Halo Nuclei

A three-cluster model developed for ternary fission studies has been applied for the first time to study the three-body structure of 2n and2p halo nuclei. For the experimentally known 2n, 2p halo nuclei, all possible ter...

Study of Neutron From a Dense Plasma Focus Paco Instrument by Means of Nuclear Tracks Detectors

A most interesting feature of dense plasma foci is the acceleration of charge particle at energy in the range of MeV per nucleon. Using deuterium gas, this devices produce fusion D-D reactions, generation fast neutron pu...

Detector Geometry Simulation Using GEANT4

Neutrino oscillation is an important phenomenon to explain the massive nature of neutrinos. this quantum mechanical phenomenon can be understood as mixing in quark sector just like the one we have in lepton sector. Obser...

Possible Alpha and 14C Cluster Emission From Hyper Radium Nuclei in The Mass Region A = 202-235

The possibilities for the emission of 4He and 14C clusters from hyper 202 235ΛRa are studied using our Coulomb and proximity potential model (CPPM) by including the lambda-nucleus potential. The predicted half lives show...

Jung’s Theorem Applied in Nuclear Track Methodology.

Nuclear track density provides accelerator beam imaging and diagnostic employing CR-39 passive detectors. Counting charged particles related tracks by automated reading systems depend on the accuracy of microscope field...

Download PDF file
  • EP ID EP569294
  • DOI 10.15415/jnp.2018.61013
  • Views 252
  • Downloads 0

How To Cite

J. S. Bogard, J. I. Golzarri, G. Espinosa (2018). Dose Calibration and Track Diameter Distribution for 241Am-Be Neutron Source, Using CR-39 Nuclear Track Methodology.. Journal of Nuclear Physics, Material Sciences, Radiation and Applications, 6(1), 77-80. https://europub.co.uk/articles/-A-569294