DYNAMICS OF PULSE SIGNAL FORMING FROM DISTAL ZONES OF RADIAL ARTERIES

Abstract

In last time new methods and hardware-software system, which combine eastern medicine traditions and western technologies are commonly used in diagnostic practice. Pulse diagnostics is one of the ancient methods for disease state identification. For diagnostic purposes different kind of arteries zones can be observed, but most popular is pulse diagnostics of wrist joints radial arteries. It is based on recording of signal from three zones, lied closely along the radial arteries of left and right hands. For the purpose of pulse diagnostics special kinds of sensing devices are used. Preliminary model with schema included acoustic impedances of artery part, soft tissues of registration zone and sensing device was proposed. In this model was assumed, that sensor occlusion force distributed between the model elements and other object structures is constant. Acoustic impedances of artery part and soft tissues were modeled by elastic component taking into consideration pulse signals spectrum. In this work modeling and experimental results of pulse signal forming by distal zone of radial artery depending on sensor occlusion force were presented. Artery stiffness was defined from the curve showing dependency between the transmural pressure and the relative change of artery volume. Stiffness evaluation results were approximated by second order polynom relative to force conformed to diastolic pressure of patient. Experimental verification of new model for vessels with small tensibility was carried out. Data were obtained for artery zone length 5 mm and pulse pressure mmHg. Artery stiffness polynomial model took into consideration fraction of occlusion force fitted the artery and soft tissues .Initial data for modeling were diastolic and pulse pressure of patient, artery diameter and length, and coefficient defining the increment of soft tissues impedance component depending on occlusive force. All dependencies were evaluated for each patient in dependency of arterial blood pressure, artery diameter and elastic response. During the simulation study artery diameter was changed in range (1,9 – 3,8) mm in compliance with measuring results obtained by another authors. Length of artery registration zone was changed until the matching of computation and experimental results. Experiment was done using the device with piezoelectric and tensoresistive sensors joined mechanical sequentially. Investigations for pulse signals from seven zones accordingly to eastern medicine canons were done for 4 patients in age 18-25 years old. Their results showed the adequacy of calculated meanings of pulse signal for different artery zone length in range of small values of occlusion forces. This fact can be explained by model affixment to the object exactly in this range. It can be suggested, that there is no interference of different zones during the pulse signal forming, when occlusive forces of sensors have value from range 0 – 2.0 N. In case of higher occlusive force values deformation of artery is starting. Consequences of deformation are that the elastic properties and pulse wave propagation process are changing. In such conditions process of pulse signal forming could not be described by elaborated model.

Authors and Affiliations

Yevhen Storchun, A. Klymukh

Keywords

Related Articles

QUANTITATIVE ASSESSMENT OF CONTRAST OF THE IMAGE ELEMENTS

One of the main tasks of image preprocessing is to improve the quality of images. The image quality is characterized by several characteristics. One of the main objective characteristics among them is the image contrast....

COMPUTER NETWORK RELIABILITY ANALYSIS BASED ON BINARY DECISION DIAGRAM

The present paper is aimed at investigating modelling and analysis techniques for the calculating the reliability of computer communication network using binary decision diagram. The network can be represented in a form...

ADAPTIVE ALGORITHM OF MOVING OBJECTS DETECTION IN VIDEO MONITORING

The paper based on the analysis of existing methods of detecting moving objects offer combined detection algorithm that adapts to such destabilizing factors as: the noise of the equipment (photoelectron matrix converter,...

FORMATION SERVICE AREA OF THE TRANSCEIVER STATION DEPENDING ON THE VARYING INPUT LOAD

The method of managing energy saving in maintaining a subscriber load by a group of service nodes of access to the network, to provide a service process at a given level of quality in the conditions of multi-channel serv...

STUDY OF THE LOAD MANAGEMENT MECHANISMS IN CONTENT DELIVERY NETWORKS

Concept content delivery network (CDN) system and load balancing mechanisms were considered in this paper. The main task of the CND network - providing the qualitative information delivery to the end user. Content Delive...

Download PDF file
  • EP ID EP461010
  • DOI -
  • Views 171
  • Downloads 0

How To Cite

Yevhen Storchun, A. Klymukh (2013). DYNAMICS OF PULSE SIGNAL FORMING FROM DISTAL ZONES OF RADIAL ARTERIES. Вісник Національного університету "Львівська політехніка", серія "Радіоелектроніка та телекомунікації", 766(2013), 202-207. https://europub.co.uk/articles/-A-461010