Dynastab S: A new concept for high energy fractures of the distal tibia

Journal Title: Ortopedia Traumatologia Rehabilitacja - Year 2004, Vol 6, Issue 4

Abstract

Background. High energy fractures of the distal tibia („pylon fractures”) usually result in severe reduction of the range of motion of the superior ankle joint. If there is severe soft tissue trauma coexisting with the fractures, the possibilities for surgical treatment are limited. Our study examined the suitability of the DYNASTAB S external fixator (for ankle joint stabilization). Material and methods. We studied 25 adult patients (15 men, 10 women), treated from April 2001 to March 2003, to whom the DYNASTAB-S stabilizer was applied for an average of 10.5 weeks.Results. In all patients bone union was achieved, with a good range of motion in the talo-crural joint. All patients tolerated the applied treatment well. The average hospital stay was 9 days. There were 2 cases of transient inflammatory reaction of the skin around the screws, and 1 case of algodystrophy syndrome, which resolved after physical treatment combined with pharmacotherapy.Conclusions. The Dynastab S external fixator is very successful in the treatment of fractures with poor prognosis in traditional methods of conservative and surgical treatment, providing bone union and good functional efficiency of the superior ankle joint. The use of the mechanical joint imitating the movement of the injured ankle joint allows for early joint rehabilitation without loss of stability of the fracture. Adaptation of the device to the operated limb is excellent. The Dynastab S external fixator can be recommended for wider use in the treatment of pylon fractures.

Authors and Affiliations

Jarosław Deszczyński, Janusz Karpiński, Marcin Ziółkowski, Artur Stolarczyk, Robert Surowiecki, Andrzej Stasiak

Keywords

Related Articles

Mobility of cervical spine and postural equilibrium in patients with spinal overload syndrome<br />.

Introduction. The spinal overload syndrome develops as a result of the gradual wearing away of the structural elements of the spine due to loads exceeding their endurance strength in the setting of reduced adaptability....

Intramedullary osteosynthesis with gamma nail in treatment of peritrochanteric fractures of the femur

Introduction. The treatment of peritrochanteric fractures of the femur, particularly in elderly people is a therapeutic challenge for the surgeon, not only due to the patient’s age but also the type of fracture. The aim...

Restytucja funkcji ręki i możliwości codziennego funkcjonowania u pacjentów leczonych operacyjnie z powodu Zespołu Kanału Nadgarstka.

Celem badań było ocenienie efektywności postępowania terapeutycznego oraz porównania funkcji ręki z subiektywnymi odczuciami pacjentów i możliwościami codziennego funkcjonowania u pacjentów po leczeniu operacyjnym Zespoł...

Comparison Analysis of Autologous Conditioned Plasma

[b]Background.[/b] Autologous Conditioned Plasma (ACP) has a wide range of potential uses in modern orthopaedics. The aim of this study was to examine the characteristics of proprietary ACP and compare them with those of...

Massive chondroma of pelvis – case report

The case of a massive pelvis chondroma in a 15-year-old male is described. The patient was previously treated operatively due to multiple chondro-osseous exostoses. An extensive chondrous tumour was detected in the patie...

Download PDF file
  • EP ID EP56199
  • DOI -
  • Views 117
  • Downloads 0

How To Cite

Jarosław Deszczyński, Janusz Karpiński, Marcin Ziółkowski, Artur Stolarczyk, Robert Surowiecki, Andrzej Stasiak (2004). Dynastab S: A new concept for high energy fractures of the distal tibia. Ortopedia Traumatologia Rehabilitacja, 6(4), 433-440. https://europub.co.uk/articles/-A-56199