Dynastab S: A new concept for high energy fractures of the distal tibia

Journal Title: Ortopedia Traumatologia Rehabilitacja - Year 2004, Vol 6, Issue 4

Abstract

Background. High energy fractures of the distal tibia („pylon fractures”) usually result in severe reduction of the range of motion of the superior ankle joint. If there is severe soft tissue trauma coexisting with the fractures, the possibilities for surgical treatment are limited. Our study examined the suitability of the DYNASTAB S external fixator (for ankle joint stabilization). Material and methods. We studied 25 adult patients (15 men, 10 women), treated from April 2001 to March 2003, to whom the DYNASTAB-S stabilizer was applied for an average of 10.5 weeks.Results. In all patients bone union was achieved, with a good range of motion in the talo-crural joint. All patients tolerated the applied treatment well. The average hospital stay was 9 days. There were 2 cases of transient inflammatory reaction of the skin around the screws, and 1 case of algodystrophy syndrome, which resolved after physical treatment combined with pharmacotherapy.Conclusions. The Dynastab S external fixator is very successful in the treatment of fractures with poor prognosis in traditional methods of conservative and surgical treatment, providing bone union and good functional efficiency of the superior ankle joint. The use of the mechanical joint imitating the movement of the injured ankle joint allows for early joint rehabilitation without loss of stability of the fracture. Adaptation of the device to the operated limb is excellent. The Dynastab S external fixator can be recommended for wider use in the treatment of pylon fractures.

Authors and Affiliations

Jarosław Deszczyński, Janusz Karpiński, Marcin Ziółkowski, Artur Stolarczyk, Robert Surowiecki, Andrzej Stasiak

Keywords

Related Articles

Pelvic osteotomy in the neurogenic unstable hip

Background. The purpose of our study was to evaluate treatment outcome in pelvic osteotomy for neurogenic hip instability, mainly in combination with soft tissue procedures, open reduction in dislocated hips, and proxima...

Sports Activity After Total Knee Arthroplasty

Background. Osteoarthritis of the knee is a degenerative disease which affects the functional status and qua­lity of life of patients. The treatment of choice in advanced stages is total knee arthroplasty (TKA). Although...

Computerized tomography evaluation of cortical bone properties in the tibia.

Background Tibia shaft fractures are among the most common fractures. However, the incidence of tibia fractures does not increase in the elderly. Osteoporotic bone resorption is possibly compensated for by periosteal app...

Powrót do aktywności zawodowej pacjentów leczonych operacyjnie z powodu koksartrozy metodą całkowitej bezcementowej aloplastyki stawu biodrowego

Wstęp. Całkowita aloplastyka stawu biodrowego jest obecnie powszechnie stosowaną metodą leczenia operacyjnego zaawansowanych postaci choroby zwyrodnieniowej stawu biodrowego o różnej etiologii. Z badań wynika, że ilość t...

Zastosowanie opatrunków aktywnych w praktyce klinicznej

Opatrunki aktywne to nowy rodzaj opatrunków, który pod wieloma względami różni się od opatrunków klasycznych. Podobnie jak opatrunki standardowe stanowią one barierę chroniącą ranę przed drobnoustrojami i zabrudzeniami,...

Download PDF file
  • EP ID EP56199
  • DOI -
  • Views 98
  • Downloads 0

How To Cite

Jarosław Deszczyński, Janusz Karpiński, Marcin Ziółkowski, Artur Stolarczyk, Robert Surowiecki, Andrzej Stasiak (2004). Dynastab S: A new concept for high energy fractures of the distal tibia. Ortopedia Traumatologia Rehabilitacja, 6(4), 433-440. https://europub.co.uk/articles/-A-56199